TO REMOVE COMBUSTION TUBE ASSEMBLY FOR

INSPECTION, CLEANING AND REPLACEMENT

SERVICE MUST BE PERFORMED BY A

QUALIFIED SERVICE AGENCY.

A.)

Turn thermostat to “OFF” or lowest

setting. Allow heater to cool.

B.)

Turn off electric power to heater.

C.)

Remove front panel.

D.)

Turn gas supply valve to “OFF”.

E.)

Disconnect gas supply line from gas valve.

F.)

From outside, remove six (6) screws

securing back of outer cabinet to air in

take and exhaust flanges. (See Figure 5).

G.)

From inside, gently slide combustion tube

assembly forward and out of outer

cabinet. (See Figure 6).

H.)

Disconnect air pressure switch tubing

from draft inducer. (See Figure 18-B).

I.)

Remove draft inducer. (See Figure 18-B).

J.)

Disconnect ignition cable and pressure

switch tubing from top of burner box.

(See Figure 16).

K.)

Remove screws securing collection box

flange and burner box flange to inner

casing top, bottom, and back.

(See Figure 19).

L.)

Pull combustion tube assembly forward

and out. (See Figure 20).

M.)

You can now inspect, clean or replace

tubular heat exchanger as needed.

NOTE: If combustion tube assembly is

being replaced, you must keep and use

collection box and burner box from

assembly being replaced.

N.)

Carefully check integrity of all gaskets

(replace as needed), then reinstall combustion

tube assembly by reversing Steps L - A.

Follow lighting instructions to put heater in

operation.

FIGURE 16

IGNITOR

IGNITOR

CABLE

PRESSURE

S W I T C H

TUBING

BURNER

BOX

FIGURE 19

FIGURE 18-B (For WOW403 / WOW404)

Circulating

Blower #2

Circuit

Board

Transformer

Junction

Box

Air Intake

Pressure

Switch

Circulating

Blower #1

Liner

Draft

Inducer

FIGURE 20