A-155, System a - 100, Doepfer – Doepfer A-155 Analog/Trigger Sequencer User Manual

Page 12: Analog / trigger sequencer

Advertising
background image

A-155

Analog / Trigger Sequencer

System A - 100

doepfer

12

fig. 5: controlling accents / dynamics

With the patch in fig. 5 you can create variable dyna-
mics or accents
within the sequence. The gain con-
trol of VCA 2 needs to be set to greater than zero (a
setting of 5 is a good starting point).

The patch in fig. 6 shows how to use the A-155 as a
16-step sequencer with one single analog CV row.
What’s needed are the Clock Divider
A-160 (output /8) and the two voltage-controlled swit-
ches in the A-150 VCS module.

With every eight clock pulses, the A-150 switches
between the two trigger and analog CV rows, so that
there’s now a 16-step trigger and CV sequence avai-
lable at the outputs of the A-150.

ADSR

VCA 1

VCF

:

Clock

VCA 2

VCO

1

2

3

4

5

6

7

8

Trig. 1

Post Out 1

Pre Out 2

ADSR

Trig. 3

A-155

Advertising