A-155, System a - 100, Controls – Doepfer A-155 Analog/Trigger Sequencer User Manual

Page 4: Doepfer

Advertising
background image

A-155

Analog / Trigger Sequencer

System A - 100

doepfer

4

3. Controls

1

Switches

The three-position toggle switches 1 are used to
select whether a particular step outputs a trigger signal
on its respective row.

Position of the upper switches:

up: trigger output on row 1 (Trig 1 output)

centre:

no trigger output

down:

trigger output on row 2 (Trig 2 output)

Position of the lower switches:

up: trigger output on row 3 (Trig 3 output)

centre:

no trigger output

down:

gate output on row 4 (Gate output)

The three upper rows produce triggers - each step that
is switched to a row will produce a short pulse like a
clock signal. The lowest row produces gates - the
signal remains "high" for the duration of the step (see
fig. 1 on the next page).

2

LEDs

The eight LEDs 2 show the sequence’s progress;
each LED lights when its respective step is active.

fig. 1: timing diagram for trigger and gate rows

3

Trig. Control

The four LEDs 3 are status indicators for the trigger
and gate rows. Each lights when a step is reached
which is switched to its own row.

Clock

Trig. 1

Gate

1

2

3

4

5

6

7

8

Trig. 1
Trig. 2
Trig. 3
Gate

Advertising