7

4. In / Outputs

!

Trigger Outputs

Sockets ! are the outputs from the three trigger rows
and the gate row.

"

Control

Alongside the four buttons for sequencer control, there
are four corresponding digital control input sockets ".

• Start

:

A signal here starts the sequence.

• Stop

:

A signal here stops the sequence.

• Clock

: A clock signal here steps through the

sequence. Also called ‘step’ input.

• Reset

: A signal here sends the sequence back to

step one.

H

Start and Stop inputs work in trigger mode.
As soon as they sense the rising edge of a
pulse, they produce a momentary signal.
The length of the pulse makes no difference
- a pulse of long duration still just produces a
momentary trigger.

Clock (step) and Reset inputs, on the other
hand, work by sensing level: so, for instance,
Reset will always be active (keeping the
sequence at step one) as long as the reset
signal is "high".

§

CV outputs, control inputs

The two groups of sockets § contain the analog CV
outputs
for each row, and the digital control inputs
for the sample-and-hold and slew limiter sections.

The upper group of sockets relates to analog CV row
1
, and the lower to analog CV row 2.

• Pre Out

:

The control voltages set on the
respective analog CV row are output
here, before (pre) passing through the
slew limiter and sample-and-hold sec-
tions.

• Post Out

: The control voltages set on the

respective analog CV row are output
here, after (post) passing through the
slew limiter and sample-and-hold sec-
tions.

Advertising