2 | product description, R404a – GEA Bock HGZ7 User Manual

Page 8

Advertising
background image

8

D
GB
F
E

09726-11.2014-DGbF

50 Hz

}

60 Hz

}

Observe the limits of application
diagrams!

1

Type designation

2

Machine number

3

Type code

4

Maximum operating current

5

Starting current (rotor blocked)

Δ: Part winding 1

YYY: Part windings 1 and 2

Y

: Part winding 1

YY: Part windings 1 and 2

6

ND (LP): max. admissible operating

pressure

(g)

Low pressure side

HD (HP): max. admissible operating

pressure

(g)

High pressure side

7

Voltage, circuit, frequency

8

Nominal rotation speed

9 Displacement
V

ND =

low pressure stage

V

HD =

high pressure stage

10 Voltage, circuit, frequency
11 Nominal rotation speed
12 Displacement
V

ND =

low pressure stage

V

HD =

high pressure stage

13 Oil type filled at the factory
14 Terminal box protection type

Electrical accessories can change
the IP protection class!

until

A018

from

A040

}

}

2| Product description

/

HGZ 7 2110-4

X

Fig. 5

2.4 Name plate (example)

2.5 Type key (example)

1)

HGZ = Hermetic gas cooled (suction gas cooled), two-stage

2)

X = Ester oil filling (HFC refrigerant R404A/R507, R410A)

3)

Possible alternative refrigerants R404A/R507, R410A, R22

R404A

Refrigerants

3

)

Number of poles
Swept volume
Size
Oil charge ²

)

Series ¹

)

1
2

4
5
6

14

13

8

12

7

11

9

10

GEA Bock GmbH
72636 Frickenhausen, Germany

Y/YY

Y/YY

3

.
.

.
.

Advertising