7.3 Spare parts recommendation

7.2 Work to be carried out
To guarantee optimum operating safety and service life of the compressor,

we recommend perfor-

ming service and checking work at regular intervals of time:

Oil change:

-

In series plants produced in the factory not mandatory.

-

In field installations or operating in the application limit range, first oil change after approx.
100 - 200 operating hours, then approx. every 3 years or 10,000 - 12,000 operating hours.

-

for NH

3

plants: oil change every year or every 5.000 operating hours.

Dispose of old oil according to the regulations, observe national regulations.

Annual checks: Oil level, tightness, running noise, pressures, temperatures, function of auxiliary
devices such as a oil sump heater, pressure switch. Comply with the national regulations!

7.1 Preparation

WARNING! Before starting any work on the compressor:

Switch off the compressor and secure it to prevent a restart.

Relieve compressor of system pressure.

Prevent air from infiltrating the system!

After maintenance has been performed:

Connect safety switch.

Evacuate compressor.

Release switch lock.