HI HLPRC03 SERIES LOAD POINT ASSEMBLY

Page 12

Specifications

Operating Specifications

Rated Output (F.S.)2+-0.002mv/v

Non-Linearity+-0.012% R.O.

Hysteresis<+-0.025% R.O.

Zero Balance<+-1.0% R.O.

Creep @ 5 Min.<+-0.010% R.O.

Temp Effect Output<+-0.0014% R.O./C (.0011
on RCHO3)

Temp Effect Sensitivity<+-0.0010% R.O./C
(.0005 on RCHO3)

Input Resistance1050 to 1200 ohms +/- 50

Output Resistance1000 +- 1 ohm +/- 10

Insulation Resistance >5000 megohms

Excitation 5-15VDC

Safe Load Limit 200% Emax

Ultimate Load 300% Emax

Safe Side Load 100% Emax

Environmental Specifications

• Operating TemperatureMinus 40

o

F to Plus176

o

F (-40

o

C to +80

o

C)

• Compensated Temperature14

o

F to 104

o

F

(Minus 10

o

C to Plus 40

o

C)

Capacity

Model #

Model #

LBS

MT

Fixed Assembly

Spare Load Sensor

66K

30

HI LPRC03-66K-45C

HI RCH03-66K

110K

50

HI LPRC03-110K-45C

HI RCH03-110K

200K

90

HI LPRBc03-200K-45C

HI RCH03-200K

TABLE 1: MODEL NUMBERS & CAPACITIES