4 message communication 3-36 – KEYENCE DL-EP1 User Manual

Page 64

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -

3-4 Message Communication

3-36

3

C

om
m

uni

ca

tin

g

w

ith FD

-M

H

Se
ries

Attributes for FD-MH Series

Designate the ID number (01H to 0AH) of a sensor amplifier as the instance ID.

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Group1

0320H

(800)

Group1

Entry count

Indicates the group 1 entry count.

Parameter range: 22

R

DINT

0321H

(801)

Sensor

amplifier

error state

*1

Indicates the error status of the sensor amplifier.

Bit 2 : Overcurrent error (ErC)

Bit 3 : EEPROM error (ErE)

Bit 4 : Fixed at 0

Bit 5 : Fixed at 0

Bit 6 : Backflow error (rEv)

Bit 8 : Temperature lower limit error

Bit 9 : Temperature upper limit error

Bit 10 : Temperature sensor connection error

(Err tEMP)

Other than the above: Fixed at 0

R

DWORD

0322H

(802) to

0323H

(803)

Reserved for system

0324H

(804)

Control output

Integration

pulse output

Abnormal

alarm output

status

*2

Indicates the control output.

Bit 0: Output 1

Bit 1: Output 2

Bit 2: Output 3

Other than the above: Fixed at 0

R

DWORD

0325H

(805)

Instantaneous

flow rate

(current

value)

*3

Indicates the instantaneous flow rate (current

value).

Parameter range:

FD-MH10A: 0.00 to 99.99

FD-MH50A: 0.0 to 999.9

FD-MH100A: 0.0 to 999.9

FD-MH500A: 0.0 to 9999.9

R

DINT

0326H

(806)

Integrated flow

rate

*4

Indicates the integrated flow rate.

Parameter range:

FD-MH10A: 0.00 to 4294967.29

FD-MH50A: 0.0 to 42949672.9

FD-MH100A: 0.0 to 42949672.9

FD-MH500A: 0 to 429496729

R

DINT

0327H

(807)

Instantaneous

flow rate

(peak hold

value)

*3

Indicates the instantaneous flow rate (peak hold

value).

Parameter range:

FD-MH10A: 0.00 to 99.99

FD-MH50A: 0.0 to 999.9

FD-MH100A: 0.0 to 999.9

FD-MH500A: 0.0 to 9999.9

R

DINT

0328H

(808)

Instantaneous

flow rate

(bottom hold

value)

*3

Indicates the instantaneous flow rate (bottom

hold value).

Parameter range:

FD-MH10A: 0.00 to 99.99

FD-MH50A: 0.0 to 999.9

FD-MH100A: 0.0 to 999.9

FD-MH500A: 0.0 to 9999.9

R

DINT

Advertising