- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -

3-4 Message Communication

3-42

3

C

om
m

uni

ca

tin

g

w

ith FD

-M

H

Se
ries

*1

You can check the error contents of the sensor amplifier according to the ON/
OFF status of each bit.
OFF(0): No error occurred. ON(1): An error occurred.
Two or more errors may simultaneously occur. For details on each error, refer to
"FD-MH Series User's Manual".

*2

You can check the detailed output status according to the ON/OFF status of
each bit.

*3

If the instantaneous flow rate exceeds the upper limit of the display range (if the
display is "FFFF"), data becomes an undefined value that exceeds the upper limit of
the display range. If the sensor amplifier display is ErH, ErS, or rEv, data becomes "0".
Without reference to the display mode set in the sensor amplifier, data for rESo mode is
used.

*4

Data is read in minimum display units without reference to the integration display
unit set in the sensor amplifier. If the integration flow rate exceeds the upper limit,
data retains the upper limit.

*5

If the temperature sensor is not connected, data becomes "0". If the
temperature exceeds the upper limit of the display (if the temperature display
is "FFFF"), data becomes an undefined value that exceeds the upper limit of
the temperature display.

*6

If the sensor amplifier display is ErH, data immediately before ErH is retained.

*7

Without reference to the display mode set in the sensor amplifier, data
becomes identical to the data within the range that can be set in "rESo" mode.

*8

If 100.0 is written, no warning is issued even if data exceeds the upper limit of
the display temperature range. A warning is issued only when data is less than
the lower limit.

*9

If 0.0 is written, no warning is issued even if data becomes less than the lower
limit of the display temperature range. A warning is issued only when data is
greater than or equal to the upper limit.

*10 If "analog output selection" is set to "standard", the free range analog becomes

invalid even if "free range analog upper limit" or "free range analog lower limit"
is rewritten.

*11 The read character string is stored as ASCII code.

For "FD-M": 4d2d4446H

Group6

03D9H

(985)

Device type

Indicates the device type.

Parameter range: 0

R

DINT

03DAH

(986) to

03DFH

(991)

Reserved for system

Class

Attribute

ID

Name

Description

Attribute

Data

Type