4-38

Chapter 4 Function Settings

4

Sample Hold 1

The instantaneous value at the time specified by external timing input is displayed, and
the value is output as shown below.

Sample hold measured value

Internal
measured value

Judgment

Measured value

Measured value

Measured value

Measured value

Measured value

Measured value

Judgment

Judgment

t

RESET

processing

ON

OFF

Timing input

Waiting for judgment

(---------- displayed)

Measured value

ON

OFF

RESET input

ON

OFF

Comparator output

ON

OFF

ON

OFF

Strobe output

BCD output

RS-232C output

Judgment awaiting output

(Comparator waiting output)

• When timing input turns ON, the internal measured value will be held. Then the value will be output.
• In the following cases, the monitor will display the result waiting status “---.-----” until the first measured

value is determined.

The LS-7000 is turned on, setting changes are made, program number changes are made, RESET
input is ON, or auto zero is input.

• Comparator output turns ON according to the measured value.
• In the above chart, the ON status of each output means that NPN open collector output is ON, provided

that it is normally open type. If it is normally closed type, the signal will be inverted.

• The ON status of each input means that the input is short-circuited to the COM terminal.
• RS-232C output is ON in synchronization with timing input if the D-SEND item as an environment setting is

set to S1 or S2 only. Refer to Data Transmission Mode on page 5-9 for environment settings in detail.

• If timing input is ON during reset processing, the monitor will display the result waiting status

“---.-----.”

• Timing input and RESET input can be under RS-232C control. Refer to

page 7-8 for details.

• Strobe output time can be changed. Refer to Strobe Output Time on page 4-

48 for details.