American Diagnostic Corporation (ADC) Adimals 2150 User Manual

Page 3

Advertising
background image

WARNING: Follow local ordinances and recycling instructions regarding disposal or recycling of the

device and device components, including batteries.

WARNING: This product may contain a chemical known to the state of California to cause cancer,

birth defects, or other reproductive harm.

CAUTION: Do not use the pulse oximeter in an explosive atmosphere.

CAUTION: SpO2 and pulse rate data is displayed for informational purposes only and does not con-

stitute a diagnosis or medical advice of any kind. Only a qualified healthcare professional should in-

terpret the data obtained on this device.

CAUTION: Check the pulse oximeter sensor application site frequently to determine the positioning

of the sensor and circulation and skin sensitivity of the patient.

CAUTION: The pulse oximeter is not for continuous monitoring.

CAUTION: Prolonged use or the patient's condition may require changing the sensor site periodically.

Change sensor site and check skin integrity, circulatory status, and correct alignment at least every 4 hours.

CAUTION: Inaccurate measurements may be caused by autoclaving, ethylene oxide sterilizing, or

immersing the sensors in liquid.

CAUTION: The device should not be used on an extremity with a blood pressure cuff, arterial

catheter, or intravascular line.

CAUTION: Do not use this pulse oximeter in situations where alarms are required. This device has

no alarm.

Brief Description of Front Panel

The PR Bar graph displays corresponding with the patient’s pulse beat. The height of the bar graph

shows the patient’s pulse strength.

Included Pulse Oximeter Accessories

One (1) lanyard

Two (2) AAA batteries

One (1) user manual

One (1) Safety Bumper

One (1) Carry Case

Battery Installation

1. Remove battery compartment top, by sliding cover in direction

of the arrow, until it pops open.

2. Insert two AAA batteries into battery compartment being sure to

observe the correct polarities. (Figure 1)

3. Replace the battery cover by reversing step 1.

Note: Be sure to observe correct battery polarity. Failure to do so might

damage the device. If device will not be used for an extended period of

time, remove batteries. Replace batteries when low battery symbol ap-

pears on display. Always replace BOTH batteries at the same time.

SpO

2

SpO

2

Pulse Rate

PR Bargraph

SpO

2

waveform

Pulse Rate

Low Power Indicator

Power
Switch

(Figure 1)

Advertising