American Diagnostic Corporation (ADC) Diagnostix 3.5v User Manual

Page 12

Advertising
background image

Conducted HF

interference

according to

IEC61000-4-6

Radiated HF

rerference cording

to C61000-4-3

3 Vrms

150 kHz to 80MHz

3 V/m

80 MHz to 2.5GHz

Not applicable
10 V/m
3 V/m

Immunity

Tests

IEC 60601

Test Level

Electromagnetic

Environment Guidelines

Guidelines and manufacturer's declaration - electromagnetic immunity

This

Diagnostix

TM

Instrument

model is intended for operation in the electromagnetic environment specified below.

The customer or the user of this

Diagnostix

TM

instrument

should ensure that it is used in such an environment.

Compliance

Level

Portable and mobile radio
equipment should not be used
within a distance from the
Diagnostix

TM

instrument, including

cables, that is less than the
recommended safety distance as
calculated by the equation that is
appropriate for the transmission
frequency.
Recommended safety distance:

d = 1.2

ߛP

d = 1.2

ߛP 80 MHz to 1000 MHz

d = 2.3

ߛP 1400 MHz to 2.5 GHz

Where P is the nominal power of
the transmitter in Watts (W) as
specified by the manufacturer of
the transmitter, and d is the
recommended safety distance in
meters (m).

The field strength of stationary
radio transmitters should be less
than the compliance level at all
frequencies as verified by an on-
site test

a

Interference is possible in the
vicinity of equipment marked with
the following symbol

Note 1: At 80 MHz and 800 MHz, the higher value applies.

Note 2: These guidelines may not apply in all situations. The propagation of electromagnetic waves is influenced by reflection and absorption by
buildings, objects and people.

a. The field strength of stationary transmitters, such as base stations of wireless telephones and mobile field radio services, amateur radio
stations, AM and FM radio and television transmitters cannot be precisely determined theoretically in advance. In order to determine the
electromagnetic environment due to stationary HF transmitters, an investigation of the location is advisable. If the field strength determined
at the location of the Diagnostix

TM

Instrument exceeds the compliance level indicated above, then the Diagnostix

TM

Instrument must be

monitored with regard to its normal operation at each place where it is used. If unusual performance characteristics are observed, additional
measures such as re-alignment of the Diagnostix

TM

Instrument or its removal to another place may be necessary.

b. In the frequency range of 150 kHz to 80 MHz, the field strength should be smaller than 3 V/m.