Dutchwest non-catalytic convection heater, Alcove installations, Construction requirements – Vermont Casting 2477 User Manual

Page 12

Advertising
background image

12

Dutchwest Non-Catalytic Convection Heater

30002314

Alcove Installations

Because of their restricted air flow and heat retention
characteristics, specific construction requirements and
special clearances apply to installations into alcoves.
No stove or chimney connector heat shields are used in
alcove installations.
ALCOVE INSTALLATION OF THE DUTCHWEST

MODEL #2477 IS PERMITTED IN BOTH THE US

AND CANADA.

Construction Requirements

The following illustrations show noncombustible ceiling
framing and maximum and minimum permitted dimen-
sions for alcove construction.

36"

(914 mm)

Max.

40" (1016 mm) Min.

ST829

Dutchwest small

Alcove floor plan

9/04 djt

Use recommended

floor protection

7/16” Du-

rock® (or

equivalent)

spaced 1” off

wood studs

on noncom-

bustible

spacers

ST829

Fig. 16 Alcove floor plan. Sheetrock on front face butts to
Durock® (or equivalent) alcove lining.

ST503

Alcove side view

11/10/00 djt

I N T R E P I D I I

Metal

Stud

Combustible

facing may

overlap

metal studs

by only 1”

1” air gap top

and bottom,

on both

sides and

back wall

7/16” Durock® (or

equivalent)

Joist Shield (Sup-

plied by Chimney

Manufacturer)

ST503

Fig. 17 Alcove side section.

St504

Alcove cutaway

11/00

ST504

Fig. 18 Cutaway perspective of alcove installation.

20" (508 mm)

14¹⁄₄"

(362 mm)

40" (1016 mm) Min.

11¹⁄₂"

(292 mm)

Min.

36"

(914 mm)

Max.

ST505

Alcove Ceiling plan

11/00

Existing Combustible

Framing

Metal studs

support 7/16”

Durock® (or

equivalent)

or sheet

metal ceiling

ST830

Fig. 19 Reflected ceiling plan.

Ceiling sup-

port package

extends 2”

below Durock®

(or equivalent)

ceiling

1” air gap,

top, bottom,

on both

sides and

back wall

ST506

Fig. 20 Front view: 79” (201 cm) minimum clearance form
hearth to combustibles on front face. Combustible facing may
overlap metal studs by only 1” (25 mm). It should not extend
below the height of the noncombustible ceiling.

NOTE: From

76” (193 cm)

to 79” (201

cm) must be

covered by a

noncombus-

tible material.

79"

(201 cm)

ST831

Dutchwest

alcove front view

9/04