Stove and chimney connector clearance charts – Vermont Casting 2477 User Manual

Page 14

Advertising
background image

14

Dutchwest Non-Catalytic Convection Heater

30002314

Corner

Corner

Parallel Installations

Installations Parallel Installations

Installations

Stove and Chimney Connector Clearance Charts

Stove Clearance

Side

Rear

3

Corner

Side

Rear

3

Corner

No heat shields

(A) 23”

(B) 24”

(C) 19¹⁄₂”

(D) 7”

(E) 19”

(F) 15¹⁄₂”

(584 mm)

(610 mm)

(495 mm)

(178 mm)

(483 mm)

(394 mm)

Rear exit,

(G) 20”

(H) 13”

N/A

N/A

N/A

N/A

flue collar heat shields

(508 mm)

(330 mm)

Top exit

1,2

, flue collar

(K) 16”

(L) 14”

(M) 11¹⁄₂”

(N) 7”

(O) 11”

(P) 9”

Single-wall connector

(406 mm)

(356 mm)

(292 mm)

(178 mm)

(279 mm)

(229 mm)

w/connector heat shield

Right Side

Right Side

and right side heat shield

Only

Only

Top exit

1

, flue collar

(K) 23”

(L) 15”

(M) 12¹⁄₂”

(N) 9”

(O) 15”

(P) 12¹⁄₂”

heat shield,

(584 mm)

(381 mm)

(318 mm)

(229 mm)

(381 mm)

(318 mm)

Double wall connector
Chimney Connector Clearance:
Single-wall connector

19¹⁄₂”

14¹⁄₂”

No connector heat shield

(495 mm)

(368 mm)

Single-wall

2

connector

9¹⁄₂”

6¹⁄₂”

w/connector heat shield

(241 mm)

(165 mm)

& flue collar heat shield
Double-wall connector

10¹⁄₂”

10¹⁄₂”

& flue collar heat shield

(267 mm)

(267 mm)

Front Clearance to Combustibles:

(All Installations)

48” (1219 mm)

Model 2477 Small Convection Heater

UNPROTECTED SURFACES

PROTECTED SURFACES

1. Shielding for a top exit stove must include a flue collar shield to protect the area behind the flue collar.
2. Chimney connector heat shields must extend exactly 24” (610 mm) above the flue collar of the stove.
3. Dimension is to the top plate of the stove, not the back wall of the stove.

Important:
When choosing an installation utilizing the side loading door located on the left side of the stove, follow the
minimum dimensions given in the Stove and Chimney Connector Chart on Page 14 and the Minimum Dimen-
sions for Noncombustible Floor Protectors given on Page 9, Figure 12.
For operation of the side loading door, the minimum clearances on the left side of the stove for usable opera-
tion is 13” (330 mm) in a corner installation and 18” (457 mm) in a parallel installation.