15

Dutchwest Non-Catalytic Convection Heater

30002314

Distance from Center of Flue Collar to Wall in Top-Exit Installations

Dutchwest Convection Heater Model 2477
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col-
lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the
wall protector.

ST427

dutchwest

flue centerline

6/30/00 djt

A

B

C

E

D

F

C

F

Chimney Connector

Side

Rear

Corner

Side

Rear

Corner

Listed, Approved

(A) 35”

(B) 13”

(C) 19⁵⁄₈”

(D) 21”

(E) 13”

(F) 19⁵⁄₈”

Double-wall, with

(889 mm)

(330 mm)

(499 mm)

(533 mm)

(330 mm)

(499 mm)

flue collar shield
Single wall, with

(A) 28”

(B) 12”

(C) 18⁵⁄₈”

(D) 19”

(E) 9”

(F) 16¹⁄₈”

Connector heat shields

(711 mm)

(305 mm)

(473 mm)

(483 mm)

(229 mm)

(410 mm)

and flue collar shield
Single wall with no

(A) 35”

(B) 22”

(C) 26⁵⁄₈”

(D) 19”

(E) 17”

(F) 22⁵⁄₈”

heat shields

(889 mm)

(559 mm)

(676 mm)

(483 mm)

(432 mm)

(575 mm)

UNPROTECTED SURFACES

PROTECTED SURFACES

Corner

Corner

Parallel Installations

Installations Parallel Installations

Installations

ST427

Advertising