7.2.2 Disconnect Function Key

Disable all the unused output ports.

A specific example of operation is described as below:
The present input and output relations are shown in Figure 7-4 (a) below:

Figure 7-4 Disconnect Function Key (a) for HX-341616 Reference

Follow the steps as below to disable the output ports including port 003、002、and 001.

Step 1:

First press down the output number keys 003, then 002 and final 001 to the

right of the blue configuration area.

Step 2:

Press the “Disconnect” key;

Step 3:

Press the previously pressed output number keys 003, then 002 and final 001

to complete the operation.