Temperature correction factors for membrane – AXEON R1-Series User Manual

Page 31

Advertising
background image

31

MKTF - 211

07/26/12

TEMPERATURE CORRECTION FACTORS FOR MEMBRANE

Find the temperature correction factor (TCF) from the table below. Divide the rated permeate flow at 77°F
by the temperature correction factor. The result is the permeate flow at the desired temperature. (See
example on the next page)