OPERATING DO’s AND DON’Ts

DO:

 Change the cartridge filters regularly

 Monitor the system and keep a daily log

 Run the system as much as possible on a continuous basis

 Adjust the system recovery to the recommended value

 Always feed the pump with filtered water

DON’T

 Permit chlorine to enter or be present in the feed water

 Shut down the system for extended periods

 Close the throttle valve completely

 Operate the system with insufficient feed flow

 Operate the pump dry

OPERATION AND MAINTENANCE

The reverse osmosis process causes the concentration of impurities. The impurities
may precipitate (come out of solution) when their concentration reaches saturation
levels.

NOTE: PRECIPITATION CAN SCALE OR FOUL MEMBRANES AND MUST

BE PREVENTED.

Check your feed water chemistry and pre-treat the water and/or reduce the system’s
recovery as required. If necessary, consult with your local dealer or distributor.