If a system is rated to produce 5 gpm of permeate water @ 77˚ F, the same system will

produce more water at a higher temperature. It will also produce less water at a lower

temperature. Use the temperature correction table to obtain the correct flow.

Example:

5 gpm @ 59˚ F (5÷1.42=3.52 gpm)

5 gpm @ 77˚ F (5÷1=5 gpm)

5 gpm @ 84˚ F (5÷0.89=5.62 gpm)

SERVICE ASSISTANCE

If service assistance is required, please complete the following process:
Contact your local dealer or distributor. Prior to making the call, have the following
information available: system installation date, serial number, daily log sheets, current
operating parameters (e.g. flow, operating pressures, pH, etc.) and a detailed
description of the problem.