TROUBLESHOOTING THE CLEANING MECHANISM

1. Fan - If the fan is not operating properly please refer to the New York Blower

manual located in this IOM manual.

2. Sweep Arm Drive – Motor not rotating.

A. Remove the motor from the gear drive and check for proper operation. If

the motor does not rotate, repair or replace.

B. If the motor does rotate properly check for binding or roughness in the

gear drive. Repair or replace one or both gear boxes as necessary.

3. Sweep Arm Drive – Motor rotating and sweep arm not rotating or rotating

intermittently.

A. Enter the clean air plenum and check for obstructions in the path of the

rotating sweep arm. Remove any obstructions

B. Verify that the sweep arm is rotating parallel to the tubesheet and that the

nozzles do not strike the cage tops and cause the sweep arm to stop.

C. Verify that the torque limiting clutch on the small sprocket is slipping.

D. Verify that the chain is not binding. If it is then check the sprocket

alignment.

E. Disconnect the drive chain. The sweep arm should rotate freely and with

no binding or roughness. If binding is experienced grease the rotary union.
If the binding or roughness continues inspect the bearing and replace if
necessary.

10-1