Warning – CAMCORP SWF with Externally Mounted Fan User Manual

Page 30

Advertising
background image

2

© Emerson Power Transmission Manufacturing, L.P. or affiliates 2003. All Rights Reserved.

TO CHANGE OUTPUT SHAFT DIRECTION

To change the hand of a unit from left hand to right hand, or vice versa, the following instructions apply:

1.

Remove drain plug and drain oil from unit.

2.

Remove end cover and seal cage capscrews; then while supporting output shaft remove end cover and shims from
the unit. (The shims may be between the seal cage/end cover and housing, or between the bearing outer race and
seal cage/end cover - do not remove the bearing race unless it is to be replaced).

3.

Remove output shaft and seal cage together from extension side.

NOTE: Keep all shims with their respective seal cage and end cover.

4.

Reassemble unit per instructions later in this manual.

UNIT DISASSEMBLY

1.

Remove drain plug and drain oil from unit.

2.

Low speed shaft (gear shaft) removal:

A. Remove end cover and seal cage capscrews.

B. With a firm hold on the output extension remove end cover and shims (The shims may be between the seal cage/

end cover and housing, or between the bearing outer race and seal cage/end cover - do not remove the bearing
race unless it is to be replaced).

C. Carefully slide output shaft assembly and seal cage out extension side.

D. Slide seal cage off low speed shaft using caution to prevent damage to seal lips.

E. Wire or tie the shims to their mating end cover and seal cages. (This only applied if the shims are between the

seal cage/end cover and housing). They will be available for reference when assembling the unit. Some units
are factory assembled with internal shims so this note may not apply.

Disconnect all before adjusting units

CAUTION

w

e

r

c

s

p

a

C

e

z

i

S

e

u

q

r

o

T

)

s

b

L

.

t

F

(

0

2

-

4

/

1

5

2

.

6

8

1

-

6

1

/

5

3

1

6

1

-

8

/

3

0

2

4

1

-

6

1

/

7

5

3

3

1

-

2

/

1

0

5

1

1

-

8

/

5

0

9

Table 1

WARNING

!

High voltage and rotating parts may cause
serious or fatal injury.

Turn off power to install or service.

Operate with guards in place.

Read and follow all instructions in this manual.

CAPSCREW

TIGHTENING

TORQUES

INTRODUCTION

The following instructions apply to RAIDER

®

Worm Gear Speed Reducers. When ordering parts or requesting information

be sure to provide all the data stamped on the reducer nameplate.

EQUIPMENT REQUIRED

In addition to standard Mechanic's tools, the following equipment is required: arbor press, wheel puller, torque wrench,
dial indicator, seal driver, bluing, adhesive sealant, snap ring pliers for internal and external rings.

GENERAL INSTRUCTIONS

Housings - Clean external surfaces of reducer before removing seal cages and end covers to
prevent dirt from falling into the unit. Record mounting dimensions of accessories for reference
when reassembling. If it is necessary to remove the reducer from its operating area, disconnect
all connected equipment and lift reducer from its foundation.

Seals - Replacement of all seals is recommended when a unit is disassembled. However, if seals
are not to be replaced, protect seal lips by wrapping shaft with plastic tape coated with oil or
grease before removing or replacing seal cage assembly. Clean the shaft but do not use any
abrasive material on the shaft surface polished by the seal.

If the reducer is painted, extreme care should be taken to mask the shaft
extensions and rubber surface of the seals. Paint on the shaft adjacent to the
seal or on the seal lip will cause oil leakage.

Advertising