Geberit tessera, Problem possible cause possible solution – Chicago Faucets Plumbing Product User Manual

Page 10

Advertising
background image

12

Geberit Tessera

TM

Toilet System

Installation & Maintenance Instructions

CHICAGO FAUCETS WARRANTY / GEBERIT BRAND PRODUCT

Geberit Tessera

TM

Toilet System

Chicago Faucets will either replace or repair the defective equipment or refund the purchase price, at its option, if an inspection by Chicago Faucets
or its authorized representative discloses any manufacturing defects in material or workmanship during this period
Chicago Faucets will not be liable for any labor or other expenses not specifically stated above, and disclaims any responsibility for incidental or
consequential damages. Warranties implied by law, including that of merchantability, are expressly limited to the period of this warranty, This limita-
tion and exclusion does not apply in those states that do not allow limitations on the duration of implied warranties. Or the exclusion may not apply
to you. This warranty gives you specific legal rights and you may have other rights, which vary from state to state.

PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

WATER CONTINUES TO RUN
INTO THE BOWL AFTER
FLUSH CYCLE IS COMPLETE

Flush valve is not seated properly.

The water level is to high in the tank. Water over-
flows into overflow tube.

Water is spraying from top of fill valve from refill
tube.

Actuator rod is improperly installed.

Water in tank is less than 1.6 GAL - 6.0 LTR.

Bowl trap way or drain line is clogged.

Hex nuts are not tighten appropriately.

Improper wall surface used to mount bowl.
Gypsum-green board, cement board, tile backer
board or ceramic tile surface are recommended
materials for mounting.

- Excess length of air tube used in installa-

tion; tube is too long to allow sufficient
air to reach from push button to lifter
assembly.

- Air tube is kinked or pinched.

- Air tube connections loose.

- Lifter assembly is misaligned

- Lifter assembly does not sufficiently

move when acturator is pushed.

Remove actuator or access panel to reach flush
valve. Pull out flush valve check seat gasket for
proper attachment. Reinstall valve test for function.

Remove actuator or access panel. Turn fill valve
adjustment rod counter clockwise to lower water
level in tank.

Remove actuator or access panel.
Replace fill valve.

Remove actuator plate reset actuator rod following
directions on page 9 position 8.

Remove actuator or access panel.
Turn fill valve adjustment rod clockwise to increase
water level in tank.

Plunge toilet bowl, if no result, use snake as nee-
ded.

Remove bolt caps, tighten hex nuts that bowl is
firmly attached to wall.

Dismount bowl, rebuild wall with material as
recommended.
PREVENT ANY SPACE BETWEEN CARRIER
FRONT AND WALL MATERIAL

Remove tank access cover, turn off water supply
stop and flush tank.
Check for and adjust excess tubing.

- Remove kinks in air tubing

- Reset air tube connections

- Remove lifter assembly from flush valve and

replace as whole.

WASTE IS NOT REMOVED
FROM BOWL

BOWL IS BECOMING LOOSE

UNCOMPLETED FLUSH
CYCLE

REMOTE ACTUATOR
UNCOMPLETED FLUSH
CYCLE