Installation Instructions

INSTALLING OPTION-FOR GE MONOGRAM

MONOGRAM INDUCTION COOKTOP

AND MONOGRAM DOWNDRAFT VENT

COMBINATION INSTALLATION ONLY.

The installation of the downdraft vent with this

cooktop requires careful consideration. Both the
cooktop and the vent must be installed according
to each specific installation instruction.

COOKTOP REQUIREMENTS

The countertop must have a deep flat surface to

accommodate the cooktop and vent. Countertops
with a rolled front edge and backsplash will not
provide the flat surface area required.

• Review the illustration to determine the countertop

surface requirements.

- All cutout clearances for this installation must be

observed.

29-7/8" SS -

29-3/4" Block

2-3/4"

22-3/8"

cutout

depth

19-5/8"

cooktop

cutout

depth

28-1/2" cooktop and vent

---- area cutout---------

1-1/32" cooktop overlap at center

--------------------*------T-----------

Front edge of countertop

1

/

8

"

gap

1-3/4" min. cooktop

cutout to rear vertical
combustible surface

23-1/2" SS

23-3/8" Block

total flat surface

required

at center

-1/2" min. clearance

to cutout

2-1/2"to

Cutout

-3/4" min. cutout to

wall, both sides

1-7/8"

BASE CABINET R EQUIREMENTS

The combined installation will fit in a standard 24"

deep base cabinet. Use a 30" or wider base cabinet.

- The vent housing, blower and ductwork will

occupy the base cabinet.

3/4"

20-3/8"

Vent

22-3/4" Inside

22" to Support Rail

T

3/4"

Thick

Support

Rail