Installation Instructions

ELECTRICAL CONNECTIONS

NEW CONSTRUCTION AND BRANCH

CIRCUIT CONNECTION

AWARNING:^

Improper connection

of aluminum house wiring to copper leads
can result in an electrical hazard or fire. Use
only connectors designed forjoining copper
to aluminum and follow the manufacturer's

recommended procedure closely.

1

U'T'gi

f

16<
Min.

Installjunction box

so that it can be

reached through

the front of the

cabinet.

When making the wire
connections, use the
entire length of conduit

provided. The conduit
must not be shortened
(unless required by local f
codes). The conduit length
is 4 ft. With the cooktop
in place, open the front of

the cabinet door. Insert
the wires from the conduit
through the opening of
thejunction box. The

conduit strain relief clamp
must be securely attached to thejunction box and
the flexible conduit must be securely attached to

the clamp.

• When installing in new construction, or

• When installing in a mobile home, or

• When installing in a recreational vehicle, or

• When local codes do not permit grounding

through neutral:

a. Insert conduit through strain relief and tighten.

b. Attach the appliance grounding lead (green

or bare copper) in accordance with local codes.

If the residence grounding conductor is

aluminum, see WARNING.

THREE-CONDUCTOR

BRANCH

CIRCUIT

CONNECTION

When connecting to a three-conductor branch
circuit, if local codes permit:

a. Connect the cooktop green ground conductor

lead to the branch circuit ground (green) using

a wire nut.

b. Connect the cooktop red lead to the branch

circuit red lead in accordance with local
codes, using a wire nut.

c. Connect the cooktop block lead to the

branch circuit block lead in accordance with
local codes, using a wire nut. If the residence
red, block or white leads ore aluminum
conductors, see WARNING.

d. Install Junction Box Cover.