To insure proper venting of this gas-fired water heater, the
correct vent pipe diameter must be utilized. Any additions or
deletions of other gas appliances on a common vent with this
water heater may adversely affect the operation of the water
heater. Consult your gas supplier if any such changes are
planned.

For proper venting in certain installations, a larger diameter

vent pipe may be necessary. Consult your local Sears Service
Center or gas supplier to aid you in determining the proper
venting for your water heater from the vent tables in the current
edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.

Periodically check the venting system for signs of obstruction

or deterioration and replace if needed.

The combustion and ventilation airflow must not be obstructed.

The water heater with draft hood installed must be connected
to a chimney or listed vent pipe system, which terminates to
the outdoors. Never operate the water heater unless it is vented
to the outdoors and has adequate air supply to avoid risks of
improper operation, explosion or asphyxiation.

• For proper draft hood attachment, the draft hood legs may

be angled slightly inward.

• Place the draft hood legs in the receiving holes on the top of

the water heater. The legs will snap in the holes to give a
tight fit. Secure two legs to top with sheet metal screws.

• Place the vent pipe over the draft hood. With the vent pipe in

position, drill a small hole through both the vent pipe and
draft hood. Secure them together with a sheet metal screw,
see Figure 17.

DRAFT HOOD

t

1 r

VENT

SCREW^'*'

.....\

DRAFT HOOD

'iff

DRAFT HOOD

All vent gases must be completely vented to the outdoors of the

structure (dwelling), install only the draft hood provided with

the new water heater and no other draft hood.

Vent pipes must be secured at each joint with sheet metal

screws.

There must be a minimum of 6 inches (153 mm) clearance
between single wall vent pipe and any combustible material.
Fill and seal any clearance between single wall vent pipe and
combustible material with mortar mix, cement, or other
noncombustible substance. For other than single wall, follow
vent pipe manufacturer’s clearance specifications. To insure
a tight fit of the vent pipe in a brick chimney, seal around the
vent pipe with mortar mix cement.

Failure to have required clearances between vent piping and
combustible material will result in a fire hazard.

Be sure vent pipe is properly connected to prevent escape of
dangerous flue gases which could cause deadly asphyxiation.

A

warning

Breathing Hazard - Carbon Monoxide Gas

Flue gases may escape if vent

pipe is not connected.
Do not store corrosive chemicals

in vicinity of water heater.
Chemical corrosion of flue and

vent system can cause serious

injury or death.

Contact a qualified installer or

service agency.

Breathing carbon monoxide can cause brain damage

or death. Always read and understand instruction manual.

Chemical vapor corrosion of the flue and vent system may
occur if air for combustion contains certain chemical vapors.
Spray can propellants, cleaning solvents, refrigerator and air
conditioner refrigerants, swimming pool chemicals, calcium
and sodium chloride, waxes, bleach and process chemicals
are typical compounds which are potentially corrosive.

FIGUF^17.

Obstructed or deteriorated vent systems may present serious
health risk or asphyxiation.

The vent pipe from the water heater must be no less than the
diameter of the draft hood outlet on the water heater and must
slope upward at least 1/4 inch per linear foot (21 mm per meter),
see Figure 18.

TO

CHIMNEY

Gas Piping

\

AWARNING

A

^

Fire

and Explosion

Hazard

è

• Do not use water heater with

any gas other than the gas

shown on the rating plate.

• Eiicessive pressure to gas

control valve can cause serious
injury ordeath,

• Turn off gas lines during

installation.

• Contact qualified installer or