CUSTOMER RESPONSIBILITIES

Thank You for purchasing a Kenmore water heater. Properly installed
and maintained, it should give you years of trouble free service. If
you should decide that you want the new water heater professionally
installed by Sears call 1-800-4-MY-HOME®. They will arrange for
prompt, quality installation by Sears authorized contractors.

Abbreviations Found in This instruction Manuai:

Carefully plan the place where you are going to put the water heater.
Correct combustion, vent action, and vent pipe installation are
very important in preventing death from possible carbon monoxide
poisoning and fires. See Figure 1.

Examine the location to ensure the water heater complies with

the

Installation Instructions

section in this manual.

CSA- Canadian Standards Association

• ANSI - American National Standards Institute

NFPA- National Fire Protection Association

• ASME - American Society of Mechanical Engineers

• GAMA - Gas Appliance Manufacturers Association

Important Information About This Water Heater:

This gas water heater was manufactured to voluntary safety
standards to reduce the likelihood of a flammable vapor ignition
incident. New technology used in meeting these standards makes this
product more sensitive to installation errors or improper installation
environments. Please review the Installation Checklist found at the
end of the installation instructions section and make any required
installation upgrades or changes.

This manual contains instructions for the installation, operation,
and maintenance of the gas-fired water heater. It also contains
warnings through out the manual that you must read and be aware
of. All warnings and all instructions are essential to the proper
operation of the water heater and your safety. Since we cannot put
everything on the first few pages, READ THE ENTIRE MANUAL

BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER
HEATER.

The installation must conform with these instructions and the

local code authority having jurisdiction. In the absence of local
codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI Z223.1/
NFPA 54. This publication is available from the Canadian
Standards Association, 8501 East Pleasant Valley Rd, Cleveland
Ohio 44131, or The National Fire Protection Association, 1
Batterymarch Park, Quincy, MA 02269.

• If after reading this manual you have any questions or do not

understand any portion of the instructions, call the Sears Service
Center.

For California installation, this water heater must be braced,

anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation procedures.

Instructions may be obtained from California’s Office of the
State Architect, 1102 Q Street, Suite 5100, Sacramento, CA
95811. Instructions can also be downloaded to your computer

at www.dsa.dgs.ca.gov/Pubs.

Massachusetts Code requires this water heater to be installed in

accordance with Massachusetts 248-CMR 2.00: State Plumbing
Code and 248-CMR 5.00.

Complies with 40 Ng/J NOx requirements of Texas and most
California AQM Districts.

A

WARNING

Excessive Weight Hazard

Use two or more people to move and install the water heater.

Failure to do so can result in injury (including back injury).

IMPORTANT: Do not remove any permanent instructions, labels, or

the data label from either the outside of the water heater or on the
inside of water heater panels.

• Remove exterior packaging and place installation components

aside.

• Inspect all parts for damage prior to installation and

start-up.

• Completely read all instructions before attempting to assemble

and install this product.

• After installation, dispose of/recycle all packaging materials.

PRODUCT SPECIFICATIONS

MODEL

NUMBER

TANK CAPACITY

iN GALS (LTRS)

TYPE

OF

GAS

INPUT

RATE

(Btu/hr)

RECOVERY

RATE GALS.

PER HOUR

@ 90°F RISE

MINIMUM

VENT PIPE

DIA. INCHES

(mm)

DIAMETER

INCHES

(mm)

DIMENSIONS

INCHES (mm)

HEIGHT TO

JACKET TOP

153.331492

40 (151)

Naturai

40,000

42.0

3(76) OR 4 (102)

20 (508)

58.14 (1477)

153.331592

50 (189)

Naturai

40,000

42.0

3(76) OR 4 (102)

22 (559)

57.28 (1455)