CARE OF YOUR REVERSE OSMOSIS SYSTEM

REVERSE OSMOSIS SYSTEM CARE GUIDE

MODEL NOs. 625.384720 & 625.384750

1. AT LEAST every 6 months, replace the prefilter and postfilter cartridges or when yellow LED flashes.

2. Replace the RO membrane cartridge when the percent rejection of total dissolved solids (JDS) is less than shown

in the specifications (see B, below) or when red LED flashes.

3. Replace the batteries once per year.

If any of the following occur before the 6 months, replace as directed.

A. Slow Making ofProciuct Water: Replace the prefilter cartridge.

If the production rate does not improve, replace the post filter car­

tridge and RO membrane cartridge.

C. Chiorfne Taste an0orOcior: Replace the prefilter, postfi Iter and
RO membrane cartridges.

B. High Tota! Dfssolvecf Solids (TDS) in Product Water: You can
get a free TDS test through some Sears retail stores or service
departments. If the store or service department does not have a

TDS meter, you can send treated and untreated water samples to

a water analysis lab for testing. It is important to test both the

treated and untreated waterto determine system performance. If
the TDS is not within the system’s performance guidelines,

replace the prefilter, post filter and RO membrane cartridges.

PROBLEM

CAUSE

CORRECTION

Chlorirm

taste andfor

odor in the RO product

water

The ppm of chlorine in your water supply

exceeds maximum limits, and has de­
stroyed the RO membrane.

If the watersupply contains more than 2.0 ppm of chlorine, addi­

tional filtering of the water supply to the RO is needed. Correct
this condition before doing maintenance on the RO system.

Replace the prefilter, post filter and RO membrane cartridges.

The prefilter is no longer removing chlo­

rine from the water supply.

Other

taste andfor odor

Post filter expended.

Replace the post filter cartridge. If taste and odor persists, re­
place the prefilter cartridge and RO membrane cartridge.

RO membrane cartridge expended.

Contamination in product water storage.

Use sanitizing procedures. Replace the post filter cartridge.

System makes product

water too slowly

Watersupply to the RO system not within

specifications.

Increase water pressure, precondition the water, etc., as needed

to conform before doing maintenance on the RO system.

Prefilter or RO membrane cartridges
plugged with sediments.

Replace the prefilter cartridge. If rate does not increase, replace

the postfilter cartridge and RO membrane cartridge.

System

makes

lower

anjount of product water
than usual

Storage tank air-charge less than 5-7

psi.

Open RO faucet and drain tank until flow slows to a drip. Keep

faucet openandchecktank pressu re. If low, pressu rize to S psi.

Close faucet to refill the tank.

High tota! dissolved sol­
ids {TDS} in product wa­
ter - flashing red LED

Watersupply to the RO system not within

specifications.

Increase water pressure, precondition the water, etc., as needed

to conform before doing maintenance on the RO system.

RO membrane cartridge expended.

Replace the prefilter, postfilter and RO membrane cartridges,

flow control, and screen.

Wafer leaking from fau­

cet airgap hole

Drain side of faucet airgap (3/8” tubing)
plugged, restricted, or incorrectly con­
nected to drain point.

Inspect and eliminate restriction or plug. Refer to installation
instructions for proper drain connection.

Continual water flow to

drain

Check valve or automatic shutoff assem­
bly plugged, restricted or parts worn

Clean, repair or replace as needed.

Faucet

LED

Indicator

light does not function af­
ter battery change

Batteries dead.

Replace with new batteries.

Batteries installed incorrectly.

Install batteries correctly.

Static protection device was not dis­

charged.

Remove batteries fora minimum or one hour and then reinstall.

Continual water flow to

drain and no product wa­
ter

Missing flow restrictor in red drain tube or
its corresponding port.

Replace flow restrictor.

Noie: Sanitizing is recommended after servicing inner parts of the system (see page 9).