DIMENSIONS and SPECIFICATIONS

15”

Supply water pressure limits ................................................ 40 - 100 psi

Supply water temperature limits............................................ 40 - 100 °F

Maximum total dissolved solids (IDS) .................................. 2000 ppm

Maximum water hardness @ 6.9 pH .................... ............... 10 gpg

Maximum iron, manganese, hydrogen sulfide...................... 0

Chlorine in water supply (max. ppm) .................................... 2.0

Supply water pH limits (pH) ..... ............................................ 4 - 1 0

Product (quality) water, 24 hours

CD ..................................... 12 gal.

Waste water per gallon of product water Q).......................... 5 gal.

Percent rejection of TDS, minimum (new membrane) ®

80 - 95

Storage tank capacity (max.) ................................................ 2.3 gal.

Automatic shutoff control....................................................... yes

Metric

280 - 690 kPa

5 - 40°C

45.42 liters

18.9 liters

8.7 liters

CD

feed water supply at 50 psi,

77'

F, and 750 TDS - Quality water production, amount of waste

water and percent rejection all vary with changes in pressure, temperature and total dissolved solids.