Step 3: install faucet (cont.), Step 4: install ro assembly – Kenmore ULTRAFILTER 300 625.384720 User Manual

Page 7

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

- STEP 3: INSTALL FAUCET (cont.)

B. ASSEMBLE FAUCET

!• Remove the large blue nut from the faucet threads.

2. Slide the three attached tubes and the telephone
style wire (monitored models only) through the sink
or countertop hole, aligning gasket under faucet
base.

3.

On the underside of the sink or countertop, screw

the nut on the faucet threads with the tubing and
wire running through the center hole of the nut.

Tighten the nut so the faucet cannot move, but do
not overtighten.

4. CONNECT TUBING TO FAUCET AS FOLLOWS.

a.

Using the 3/8" x 1/4" tubing adaptor, connect

the

1/4" blue

tubing from the faucet to the

3/8" blue

tubing from the RO.

Note: See pages 13 and 14 for tubing connection in­

structions.

b.

Using the 1/4" x 1/4" tubing adaptor, connect

the 1/4"

red

tubing

from

the faucet to the 1/4"

red

tubing from the RO.

c.

Monitored models only: Connect the telephone

style wire to the receptacle on PWA board in the RO
manifold and route the wiring through holes in top
cover and manifold assembly.

— STEP 4: INSTALL RO

ASSEMBLY -

Flang the assembly on the included hanger washers,
or lay on the cabinet floor, as desired.

1. Refer to FIG, 7 for wall mounting, Flold the assem­
bly up to the wall surface and mark locations for the
hanger washers. Distance needed is 7.2" (approx.
7-7/32") apart.

2. Install hanger washers at least 15-1/2" up from the
cabinet floor, allowing room to remove sumps from
filter heads. Wood screws are provided, or obtain
other fasteners as needed.

Problems, Questions? Call 1 -800-426-9345 Kenmore Water Une

Advertising
This manual is related to the following products: