INSTALLATION OF THE RANGE

ELECTRICAL CONNECTIONS (cont)

6. 3-Wire Conduit Installation

a. Loosen the 3 lower terminal screws from the terminal

block, insert the center bare wire (white/neutral) tip
through the bottom center terminal block opening.. On
certain models, the wire will need to be inserted
through the ground strap opening and then into the
bottom center block opening., insert the two side bare
wire tips into the lower left and the tower right terminal
block openings.. Tighten the screws until the wire is
firmly secure (approximately 20 inch-lbs,).

DO NOT remove the ground strap connectiorr.

NOTE: ALUMINUM WIRING:

Aluminum building wire may be used but it must be
rated for the correct amperage and voltage to make
connection, Connect wires according to this Step 6 or
Step 7 depending on number of wires.

wire tips

Bracket'

Conduit

Wire used, location and enclosure of splices, etc,,
must conform to good wiring practices and local
codes.

b. Skip to Step 8 and proceed with the installation.

7. 4-Wlre Conduit Installation

a. Loosen the three lower terminal screws from the

terminal block. Remove the ground screw and the
ground plate and retain them . Cut and discard the
ground strap. DO NOT DISCARD ANY SCREWS.

b. Insert the ground bare wire tip between the range

frame and the ground plate {removed earlier) and
secure it in place with the ground screw (removed
earlier). Insert the bare wire (white/neutral) lip through
the bottom center of the terminal block opening. Insert
the center two side bare wire tips into the lower left and
the lower right terminal block openings. Tighten the
screws until the wire is firmly secure (approximately 20
inch-lbs,).

Before

After

Bracket

Wire used, location and enclosure of splices, etc.,
must conform to good wiring practices and local
codes,

c. Proceed to Step 8.