CONNECTING THE WATER LINE

BEFORE YOU BEGIN

This water line installation is not warranted by the
refrigerator or icemaker manufacturer. Follow these
instructions carefully to minimize the risk of expensive
water damage.

Water hammer (water banging in the pipes) in house
plumbing can cause damage to refrigerator parts and lead
to water leakage or flooding. Call a qualified plumber to
correct water hammer before installing the water supply
line to the refrigerator.

To prevent burns and product damage, do not hook up
the water line to the hot water line.

If you use your refrigerator before connecting the water

line, make sure the icemaker power switch is in the O (off)
position.

Do not install the icemaker tubing in areas where

temperatures fall below freezing.

When using any electrical device (such as a power drill)
during installation, be sure the device is double-insulated
or grounded in a manner to prevent the hazard of electric
shock, or is battery-powered.

All installations must be in accordance with local plumbing
code requirements.

NOTE: Wear eye protection.

WHAT YOU WILL NEED

• Copper Tubing, 1/4" outer

diameter to connect the refrigerator
to the water supply. Be sure both
ends of the tubing are cut square.

To determine how much tubing you need: measure
the distance from the water valve on the back of the
refrigerator to the water supply pipe. Then add 8 feet

(2.4 m). Be sure there is sufficient extra tubing (about

8 feet [2.4 m] coiled into 3 turns of about 10" [25 cm]
diameter) to allow the refrigerator to move out from the
wall after installation.

• A cold water supply. The water pressure must be

between 20 and 120 p.s.i. on models without a water

filter and between 40 and 120 p.s.i. on models with a
water filter.

• Power drill.

• 1/2" or adjustable wrench.

• Straight- and Phillips­

blade screwdriver.

• Two 1/4" outer diameter

compression nuts and
2 ferrules (sleeves) to
connect the copper tubing to
the shutoff valve and the

refrigerator water valve.

* If your existing copper water

line has a flared fitting at the
end, you will need an
adapter (available at
plumbing supply stores) to
connect the water line to the
refrigerator OR you can
cut off the flared fitting with a tube cutter and then use
a compression fitting.

• Shutoff valve to connect to

the cold water line. The
shutoff valve should have a
water inlet with a minimum
inside diameter of 5/32" at
the point of connection to the
COLD WATER LINE. Saddle-type shutoff valves are
included in many water supply kits. Before purchasing,
make sure a saddle-type valve complies with your local
plumbing codes.

NOTE: Self Piercing Saddle Type Water Valve should
not be used.

INSTALLATION INSTRUCTIONS

Install the shutoff valve on the nearest frequently used

drinking water line.

1. SHUT OFF THE MAIN WATER SUPPLY

Turn on the nearest faucet to relieve the pressure on
the line.

2. CHOOSE THE VALVE LOCATION

Choose a location for the valve that
is easily accessible. It is best to
connect into the side of a vertical
water pipe. When it is necessary to
connect into a horizontal water pipe,
make the connection to the top or
side, rather than at the bottom, to
avoid drawing off any sediment from the water pipe.

3. DRILL THE HOLE FOR THE VALVE

Drill a 1/4" hole In the water
pipe using a sharp bit. Remove
any burrs resuiting from drilling

the hole In the pipe. Take care
not to allow water to drain into
the drill.

Failure to drill a 1/4" hole may
result in reduced ice production or smaller cubes

29