Installation Instructions (cont’d)

Venting (cont’d)

CUTTING

OPENING

THROUGH

AN

OUTSIDE

WALL AND COLLAR INSTALLATION

After reading the manual and you have determined the location
of the opening in the wall, (using the drawing below), cut a 3/;"

hole through an exterior wall.

NOTE; When determining location of the opening in the

outside wall allow for the

'/"

rise per foot that has taken

place in the horizontal run.

CONNECTING

PVC,

ABS

OR

CPVC

PIPE

VENT

TO

BLOWER

1. The manufacturer has supplied a 3" PVC Schedule 40 street

elbow for connection to the water heater when turning imme­
diately horizontally off the blower. Place the elbow in the

required direction on the blower and using 3 sheet metal
screws, attach the elbow.

The 3 ' PVC, ABS or CPVC Schedule 40 vent pipe can be run

from the water heater through the wall or from the wall to the

water heater, whichever is most convenient. The vent pipe must

extend a minimum of I/

2

" through the exterior wall. Extending

the vent cap as far as possible from the surface of the exterior

wall will help minimize discoloration of the wall in this area

which may be caused by the flue gases. Note that the inside col­
lar must be slipped over the vent piping before locating the pipe
through the wall. Before securing the inside and outside collars
to the wall, use a silicone sealer between pipe and opening to

insure a water and air tight seal.

2. If there is to be a vertical run of vent from the blower, the 3"

PVC or ABS pipe must be attached to the blower using 3 sheet
metal screws. Additionally, you must seal all joints using a suit­
able silicone sealer such as GE RTV-103 or equivalent.

INSTALLATION SHOWING USE OF PVC, ABS OR

CPVC PIPE