Installation Instructions (cont’d)

Installation Checklist

BEFORE LIGHTING THE PILOT;

Check the gas lines for leaks.
a. Use a soapy water solution. DO NOT test for gas leaks

using a match or open flame.

b. Brush the soapy water solution on all gas pipes, joints and

fittings.

c. Check for bubbling soap. This means you have a leak.

Turn “OFF” gas ana make the necessary repairs.

d. Recheck for leaks.
e. Rinse off soapy solution and wipe dry.

Is the new temperature-pressure relief valve properly installed
and piped to an adequate drain? See “Temperature-Pressure
Relief Valve” section.

Are the cold and hot water lines connected to the water

heater correctly? See “Water Piping” instructions in the
“Installing the New Water Heater” section.

Is the water heater completely filled with water? See “Filling”
instructions in the “Installing the New Water Heater” sec­
tion.

Will a water leak damage anything? See the “Locating the
New Water Heater” section.

Is there proper clearance between the water heater and any­
thing that might catch fire? See the “Locating the New water
Heater” section.

Do you have adequate ventilation so that the water heater

will operate properly? See “Combustion Air and Ventilation”

in the “Locating the New Water Heater” section.

Is the draft hood vent piping properly secured? See “Venting”
instructions in the “Installing the New Water Heater” sec­
tion.

Is there proper clearance between the vent pipe and anything
that might catch on fire? Sec “Venting” instructions in the
“Installing the New Water Heater” section.

Is the vent pipe properly sloped and does the vent terminate
outdoors? See “Venting” instructions in the “Installing the
New Water Heater” section.

Do you need to call your gas company to check the gas pipe
and its hookup?

VENT PIPE TO

OUTDOORS

COLD

TEMPERATURE-

PRESSURE RELIEF

VALVE

DISCHARGE PIPE

(Do not cap or plug)

"AUTCaiATIC STORAGE WATER

HEATER" SUITABLE FOR HATER

(POTABLE) HEATING ONLY

kiiooeL MUMiu-n • rAMmy

EOUIPPCO

FOR INPUT MOOVERY

Ь.в.вAЙ..

ANSaviO

SCRM.NUM»

OAS BOmn (MUMR.

MAXIMUM HVDROSTATIC (U9 PNESSUnC N W.C

lAORNNimCHUM IMJLWUT HH.MfT PI«HU(K HMNFCUI

150

P.9.I. W.C. W.C W.C

MODEL RATING PLATE

20

Advertising