Installation Instructions (cont*d)

Temperature-Pressure Relief Valve

AWARNING

At the time of manufacture this vnter heater was provided
with a combination temperatune^ressures relief valve certified
b/ a nationally recognized testing laboratory that maintains

periodic inspection of production of listed equipment or mate­

rials, as meeting the requirements for Relief Valves and
Automatic Gas Shutoff De^es for Hot Water Supply Systems,

and the latest edition of ANSI Z2I.22 and the code require­
ments of ASME. If replaced, the valve must meet the require­

ments of local codes, but not less than a combination tempera­

ture and pressure relief valve certified as meeting the require­

ments for Relief Valves and Automatic Gas Shutoff Devices for
Hot Water Supply Systems, ANSI Z2I.22 by a nationally recog­
nized testing laboratory that maintains periodic inspection of

production of listed equipment or materials.
The valve must be marked with a maximum set pressure not

to exceed the marked hydrostatic working pressure of the
water heater (ISO IbsJsq. in.) and a discharge capacity not less
than the water heater input rate as shown on the model rating

plate. (Electric heaters ■ watts divided by 1000 x 3415 equal
BTU/Hr. rate.)
Your local jurisdictional authority, while mandating the use of a

temperature-pressure relief valve complying with ANSI Z21.22
and ASME, may require a valve model different frtmi the one
fiirnished the water heater.

Compliance vrith such local requirements must be satisfied by
the installer or end user of the water heater with a locally pre­
scribed temperature-pressure relief valve installed in the deslg

nated opening in the water heater in place of the factory fur­

nished ràlve.
For safe curation of the water heater, the relief valve must not

be removed from itis desifpiated opening or plugged.
The temperature-pressure relief valve must be installed directly

into the fitting of the water heater designated for the reftef valve.

Position the valve downvwud and provide tubing so that any dis-

chai^ will exit only witiiin 6 inches above, or at any distance

below the structiiral floor. Be certain that no contact is made
with any live electrical part The discharge opening must not be
blocked or reduced in size under any circumstances. Excessive
length, over 30 feet or use of more tiian four elbows can cause
restriction and reduce the discharge capacity of the valve.

No valve or other obstruction is to be placed between the relief
valve and the tank. Do not connect tubing directly to discharge
drain unless a fi" air gap is provided. To prevent bodily injury, haz­
ard to life, or property damage, the relief valve must be allowed

to discharge water in quantities should circumstances demand. If
the discharge pipe is not connected to a drain or other suitable

means, the water flow may cause property damage.
The Discharge Pipe;

• Must not be smaller in size than the outlet pipe size of the

valve, or have any reducing couplings or other restrictions.

• Must not be plugged or blocked.
• Must be of material listed for hot water distribution.
• Must be installed so as to allow complete drainage of both

the temperature-pressure relief valve, and the discharge

pipe.

• Must terminate at an adequate drain.

• Must not have any valve between the relief valve »id tank.

AWARNING

The

temperature-pressure

relief

valve

must

be

manually

operated at least once a year. Caution should be taken to
ensure that (I) no one Is in front of or around the outlet of

the temperature-pressure rriief valve dlsdiaige line, and (2)

the water manually discharged will not cause any bodily

injury or property damage because the water may be
extremely hot

If after manually operating the valve, it foils to completely
reset and continues to release water, immediately dose the
cold water inlet to the water heater, follow the draining
insteuctions,

and

replace

the

temperature-pressure

relief

valve with a new one.

COLD

TEMPERATURE-

PRESSURE

RELIEF VALVE

DISCHARGE PIPE
{Do not cap or plug)

6" AIR GAP

RELIEF VALVE OPENING

At the time of manufectu«, this water heater was provided with a lombinatior tem-

perature.prej$ure relief valve listed as compl)dn

2 with the standard for relief valves and

automatic gas shut-off devices for hot water supply systems, ANSI 221.12. for safe

operation of the water heater, the relief valve must not be removed from its designated

point Of fostailacion or plugged.
Your loc^ [urisdictional authority, while mandating the use of a temperature-pressure

relief valve complying with ANSI Z21.22 and ASME may require a valve model different

from the one furnished with the water heater.
Compiiarce with such local requirements must be satisfied by the installer or end user

of the water heater with a locally prescribed temperature^iressure relief valve installed

in the designated opening in the water heater.
See manual heading -‘Temperature-Pressure Relief Valves" for installation and mainte­

nance of relief valve, discharge line, and ocher safety precautions.