Pressure Drop (PSI) vs. Flow Rate (GPM)

FIG. 50

Intermittent flow rate does not represent the maximum service flow rate used for determining the soften­

ers rated capacity and efficiency. Continuous operation at flow rates greater than the service flow rate
may affect capacity and efficiency performance.

OTHER SPECIFICATIONS

MODEL 38356

MODEL 39356

Type of ion exchange material (resin)

high capacity

high capacity

Amount of resin (cu. ft.)

0.92

0.92

Rated Softening Capacity (Grains @ Pounds Salt Dose)

14,200 @ 2.8

29,900 @ 8.8

35,600 @ 14.7

14,200 @ 2.8

29,900 @ 8.8

35,600 @ 14.7

Efficiency Rating (Grains / Pound of Salt @ Minimum Salt Dose)

5060 @ 2.8

5060 @ 2.8

Rated Service Flow Rate (gpm)

8.0

8.0

Pressure Drop at Rated Service Flow Rate (psi)

14

14

Intermittent Flow Rate @ 15 psi (gpm)

8.5

8.5

Max. Drain Flow Rate (gpm)

2.0

2.0

These systems conform to NSF / ANSI 44 for the specific performance claims as verified and substantiat­
ed by test data.
The efficiency rating is only valid at the minimum stated salt dosage. These softeners were efficiency

rated according to NSF / ANSI Standard 44.

Questions? Call The Kenmore Water Line 1-800-426-9345