Install Covers and Restart Water Heater

INSTALL COVERS

After installing your water softener, replace the covers. Angle
the covers so the main cover clips onto the back first, then

bring down in front and clip on the two (2) tabs inside the rim
of the salt hole and lower the salt cover closed. See Fig. 23.

RESTART THE WATER HEATER

Turn on the gas (or electric) supply to the water heater and

light the pilot.

YOUR PLUMBING INSTALLATION AND ELECTRICAL
WORK ARE NOW COMPLETE.

Cover

(Main)

Salt Hole
Cover

FIG. 23

Program The Timer

Salt Level Adjust

Silt .

-

I.i-vi;! '

Signal Light

Adjust

mUtS0c

Display

REGENERATION Button

InicIHSoft Pf:rffirrnoncf:

Copadty Pius a

Ultrodeansing

Sill! yank Light

UP Button

■ DOWN Button

Tank Light

PROGRAM THE TIMER

1. When the transformer is plugged in, a model code

(H 32), and a test number (example: J1.1) show in the

face plate display for 4 seconds. Then, 12:00 AM and

PRESENT TIME

begin to flash.

NOTE: If “

--- ”

shows in the display, press the UP

or DOWN button until H 32 shows in the display.

Then, press the SELECT button to set, and change
to the flashing PRESENT TIME display.

2. To check the model code, unplug the transformer at the

wall outlet and plug in again. If other than H 32 shows,

refer to the Troubleshooting Section.

SOUND “BEEPER”: A “beeper” sounds while pressing
buttons for timer setup. One beep signals a change in
the face plate display. Repeated beeps mean the timer
will not accept a change from the button you have
pressed, telling you to use another button. For example,
while setting the hardness the beeper sounds repeated­
ly when the display reaches 1 using the DOWN button,
or the highest hardness setting using the UP button.

SELECT

FIG. 24

H 3d

I I I

J

I, I

I “f,nn

7

IC'LIIJ

5

PRESENT TIME

4
3
2

~ --

FIG. 25

Questions? Call The Kenmore Water Line 1-800-426-9345

17