Service Tech Information

MANUAL ADVANCE REGENERATION CHECK

This check verifies proper operation of the valve motor,

brine tank fill, brine draw, regeneration flow rates, and
other controller functions. Always make

the initial

checks, and the manual initiated diagnostics.

NOTE: The faceplate display must show a steady

time (not flashing). If an

error

code shows, first

press the SELECT1 button to enter the diagnostic

display.

1. Press the REGENERATION button and hold in for 3

seconds. *RECHARGE and Fill begin to flash (or
clean backwash begins, if set) as the softener enters
the fill cycle of regeneration.

* NOTE:

If the CLEAN feature is set to ON, a clean­

ing backwash (CLEAN and Bkwsh or Rinse flashes

in the display, along with the minutes of the clean

cycle remaining), precedes the recharge.

2. When FILL is on steady, remove the brinewell cover

and, using a flashlight, observe fill water entering the
tank.

3. If water does not enter the tank, look for an obstruct­

ed nozzle, venturi, fill flow plug, brine tubing, or brine
valve riser pipe.

CYCLE FLOW RATES (GALLONS PER

MIN.)

FILL (flow to salt storage tank)

0.3 (1.1 liters)

BRINING (flow to drain)

.22 (.83 liters)

BRINE RINSE (flow to drain)

.15

(.57

liters)

MAX. BACKWASH (flow to drain)

2.0

(7.6

liters)

MAX. FAST RINSE (flow to drain)

2.0

(7.6

liters)

4. After observing fill, press the REGENERATION but­

ton to move the softener into brining. A slow flow of
water to the drain will begin. Verify brine draw from
the brine tank by shining a flashlight into the brinewell
and observing a noticeable drop in the liquid level.

NOTE: Be sure a salt bridge is not preventing water

with salt contact.

5. If the softener does not draw brine:

• nozzle and/or venturi dirty or defective.
• nozzle and venturi not seated properly on gasket
• restricted drain (check drain fitting and hose)
• defective nozzle and venturi seal
• other inner valve defect (rotor seal, rotor & disc,

wave washer, etc.)

NOTE: If water system pressure is low, an elevated

drain hose may cause back pressure, stopping

brine draw.

Brine Valve

FIG. 65

6. Again press REGENERATION to move the softener

into backwash. Look for a fast flow of water from the
drain hose.

7. An obstructed flow indicates a plugged top distributor,

backwash flow plug or drain hose.

8. Press REGENERATION to move the softener into

fast rinse. Again look for a fast drain flow. Allow the
softener to rinse for a few minutes to flush out any

brine that may remain in the resin tank from the brin­
ing cycle test.

9. To return the softener to service, press REGENERA­

TION once more.

Questions? Call The Kenmore Water Line 1-800-426-9345