Filili – Kenmore THE ECONOMIZER 153.33205 User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

4. Make sure that the plastic tubing is still attached from the air pressure

switch to the port on the blower housing. Make sure the plastic
tubing is not folded anywhere between the pressure switch and
the blower housing.

5. Make sure the ON/OFF switch is in the OFF position and that the

outer harness is connected from the blower control box to the
connector on the bottom side of the gas valve.

6. If the outer harness is notfactory installed, make sure flie ON/OFF switch

is in the OFF position and then connect the harness from the blower
control box to the connector on the bottom side of the gas valve.

filili

Before servicing the water heater, mate sure the blower

assembly is unpluggaJ or the eiectrkal supply to the
water heater is turned "OFF".

• Label all wires prior to disconnection when setvcing

controls. Wiring error can cause improper and dangerous
operation. Veriy proper operation after sen/idng.

• Failure to do this aruld resul in death, serious bodily

injury, or pioperly darmge.

7. Do not plug in power cord until vent system is completely installed.

This power vent heater operates on 110-120 Vac, therefore a
grounded outlet must be within reach of the six (6) foot (1.8 m)
flexible power cord supplied with the unit (see Figure 1). The power
cord supplied may be used only where local codes permit. If local
codes do not permit the use of a flexible power supply cord:

a. ) Make sure the unit is unplugged from wall outlet. Remove screws

and open panel on front of control box.

b. ) Cut the fiexibie power cord, leaving enough to be able to make

connections and remove the strain relief fitting from box.

c. ) Install suitable conduit fitting in side of enclosure and then follow

(d.) and (e.) below.

d. ) Splice field wiring into existing wiring using code authorized method

(wire nuts, etc.).

e. ) Be certain that neutral and live connections are not reversed when

making these connections.

f.

) Close panel on the side of control box, make sure that access panel

is secured shut.

16

Advertising
This manual is related to the following products: