Faceplate, Fig. 51, Always make these initial checks first – Kenmore 625.38356 User Manual

Page 35

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

FACEPLATE

InteiliSoft

Snlt .

i-sve! -

/ Set

!i-vt-i /5:;jrrîi

' Sdtcf

;

......... .......J''

Low

Rijg<:n 5

Sait

N/.Í

Adjust/'ibie Low Suit Inclicator

FIG. 51

Keep this manual with your water softener. If repairs are

needed, the service technician must have the informa­

tion on the following pages.

ALWAYS MAKE THESE INITIAL CHECKS FIRST

1. Does the time display show the correct time of

day?

• If display is blank, check power source to the sof­

tener.

• If time is flashing, power was off for over 6 hours.

The softener resumes normal operation but regen­

erations occur at the wrong time.

• If an error code (Example: Err3) shows in the face­

plate display, go to AUTOMATIC ELECTRONIC

DIAGNOSTICS.

2.

Plumbing bypass valve(s) must be fully in service

position.

3. The inlet and outlet pipes must connect to the

softener inlet and outlet respectively.

4. Is the transformer plugged into a “live”, grounded

wall outlet, and the power cable fastened secure­
ly to the controller?

5. The valve drain hose must be free of kinks and

sharp bends, and not elevated over 8 ft. above

the floor.

6. Is there salt in the storage tank?

7.

Is the brine tubing connected? Brine tubing con­
nects to nozzle venturi and brine valve assembly.

8. Is the brine valve float set right?

9. Press the SELECT button two times to display the

hardness setting.

Be sure it is the correct setting for the household’s

water supply. (Make a hardness test of the raw water

and compare with the hardness setting. Also test a

soft water sample to verify if a problem exists.) Press

the SELECT button twice more to return to present

time in the display.

If you do not find the problem after making initial

checks, do the

MANUAL

INITIATED ELECTRONIC

DIAGNOSTICS, and the MANUAL ADVANCE REGEN­

ERATION CHECK.

Questions? Call The Kenmore Water Line 1-800-426-9345

35

Advertising