Service Tech Information

W/VTER FLOW THROUGH THE SOFTENER VALVE

BACKWASH CYCLE

BACKWASH CYCLE

Timer/switch action again allows the motor to turn

the rotor & disc to place the valve in BACKWASH,

stopping water flow to the nozzle. Water is routed

down and out the bottom distributor, up through

the bed, and out the top distributor to the drain.

The fast flow (controlled by a flow plug in the drain

fitting) flushes dirt, sediments, iron deposits,

remaining brine and hardness to the drain.

FIG. 62

FAST RINSE CYCLE

During FAST RINSE, the rotor & disc is positioned

so water flow enters the resin tank through the top

distributor, and exits through the bottom distributor,

to the drain.

The electronic timer again energizes the motor to

return the valve to service. As the valve rotates,

the position switch lever drops to open the circuit.

The valve remains positioned in service until the

electronic timer initiates the next regeneration.

FAST RINSE CYCLE

FIG. 63