Service Tech Information

TROUBLESHOOTING

VALVE POSITION INDICATORS:

Depending on the valve position, the following indica­

tors show in the display:

Indicator

Valve Position

Serv

.....................................Service

Fill

....................................... Fill

Brine

....................................Brining/Brine Rinse

Bkwsh

..................................Backwash

Rinse

................................... Fast Rinse

When the valve Is rotating from one cycle to another,

both Indicators flash. For example. If the valve Is In

transition between fill and brining, both

Fill and Brine

flash. Upon reaching brining position. Fill goes off and

Brine Is on steady. The time display shows the minutes

of the cycle remaining.

NOTE: If the faceplate is left in a diagnostic display
(or a flashing display when setting times or hard­
ness), present time automatically returns if a button

is not pressed within 4 minutes. To return to the
diagnostic display, repeat step 1.

OTHER INFORMATION

While In this diagnostic screen, the following Information

Is available and may be beneficial for various reasons.

This Information Is retained by the computer from the

first time electrical power Is applied to the faceplate.

• Press and hold the UP button to display the number of

days this faceplate has had electrical power applied.

• Press and hold the DOWN button to display the num­

ber of regenerations Initiated by this faceplate since

the model code number was entered.

• Press the RECFIARGE button to advance the valve to

each position and observe the switch and position

Indicators to verify component operation, or to possi­

bly Isolate a defect.

• Press and hold the SELECT button for 3 seconds until

a model code shows In the display, see Fig. 56.

This code Identifies the softener nominal capacity

size. If the wrong number shows, the softener will

operate on Incorrect data. Do the following as needed.

If the correct model code (S 32) shows:

Press the

SELECT button to return to the present time display.

To change the number:

Press the UP or DCWN but­

ton until the correct model code (S 32) shows. Then,

press the SELECT button and reset the timer.

TIMER PWA REPLACEMENT

Be sure the valve is in service position when
replacing the timer PWA (observe valve cycle indi­
cator).

If after Installing and programming the replace­

ment timer PWA, the valve Is not In service position, do

the following to assure correct cycle orientation, or tim­

ing, between the faceplate and valve.

Use the MANUAL ADVANCE procedures with the

REGENERATICN button, advance through the

recharge cycles until the valve stops In service position,

and RECFIARGE no longer flashes In the display.

NOTE: The valve motor may automatically drive

through several valve positions while searching for

service. If an error code occurs, unplug the trans­

former, then plug in again.

FIG. 56