Installation Checklist

BEFORE LIGHTING THE PILOT:

Installation Instructions (cont'd)

• Check the gas lines for leaks.

a. Use a soapy water solution. DO NOT test for gas leaks

using a match or open flame.

b. Brush the soapy water solution on all gas pipes, joints and

fittings.

c. Check for bubbling soap. This means you have a leak.

Turn “OFF” gas and make the necessary repairs.

d. Recheck for leaks.
e. Rinse off soapy solution and wipe dry,

Is the new temperature-pressure relief valve properly installed

and piped to an adequate drain? See “Temperature-Pressure

Relief Valve" section.

Are the cold and hot water lines connected to the water

heater correctly? See “Water Piping” instructions in the

“Installation Instructions" section.

Is the water heater completely filled with water? See “Filling”

instructions in the “Installation Instructions” section.

Will a water leak damage anything? See the “Facts to

Consider About the Location” section.

Is there proper clearance between the water heater and any­

thing that might catch fire? See the “Facts to Consider About
the Location” section.

Do you have adequate ventilation so that the water heater

[e propeny?

in the “Installation Instructions” section.

will operate properly? See “Combustion Air and Ventilation”

VENT PIPE TO

OUTDOORS

OR CHIMNEY

HOT

SHUTOFF VALVE

COLD

GAS SUPPLY

SHUTOFF

VALVE

Is the draft hood vent piping properly secured? See “Venting”

instructions in the “Installation Instructions” section.

Is there proper clearance between the vent pipe and anything

that might catch on fire? See “Venting” instructions in the
“Installation Instructions” section.

Is the vent pipe properly sloped and does the vent terminate

outdoors? See; “Venting” instructions in the “Installation
Instructions" section.

• Do you need to call your gas company to check the gas pipe

and its hookup?

TEE

DRIF LEG

(Sediment trap)

PIPE CAP

DRAIN VALVE

TEMPERATURE-

PRESSURE

RELIEF VALVE

DISCHARGE PIPE

(Do not cap or plug)

6” AIR GAP