A warning, Awarning, Safety precautions – Kenmore ECONOMIZER 153.332418 User Manual

Page 2: I i i

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Safety Precautions

A WARNING

Improper

installation,

adjustment,

alteration,

service

or

maintenance

can

cause

DEATH,

SERIOUS

BODILY

INjURV, OR PROPERTY DAMAGE. Refer to this manu­

al for assistance or consult your local Sears Service

Center for further information.

AWARNING

WATER

HEATERS

EQUIPPED

FOR

ONE

TYPE

GAS

ONLY: This water heater is equipped for one type gas
only. Check the model rating plate near the gas control

valve for the correct gas. DO NOT USE THIS WATER

HEATER

WITH

ANY

GAS

OTHER

THAN

THE

ONE

SHOWN ON THE MODEL RATING PLATE. Failure to

use the correct gas can cause problems which can result in

DEATH,

SERIOUS

BODILY

INJURY,

OR

PROPERTY

DAMAGE. If you have any questions or doubts consult

your gas supplier or local utility.

AWARNING

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ­

UIDS

(VAPORS)

ARE

LIKELY

TO

BE

PRESENT

OR

STORED

(GARAGES,

STORAGE,

AND

UTILITY

AREAS,

ETC);

Flammable

liquids

(such

as

gasoline,

solvents,

propane (LP) or butane, etc.), all of which emit flammable
vapors, may be improperly stored or used in such areas.
The gas water heater pilot light or main burner can ignite

such vapors. The resulting flashback and fire can cause
death or serious burns to anyone in the area, as well as

property damage.

If installation in such areas is your only option, then the

installation must be accomplished in a way that the pilot

flame and main burner flame are elevated from the floor

at least 18 inches. While this may reduce the chances of
flammable vapors from a floor spill being ignited, gasoline
and other flammable substances should never be stored or

used in the same room or area containing a gas water
heater or other open flame or spark producing appliance.
NOTE: Flammable vapors may be drawn by air currents

from other areas of the structure to the appliance.

AWARNING

If this water heater will be used in beauty shops, barber
shops, cleaning establishments, or self-service laundries

with dry cleaning equipment, it is imperative that the

water heater or water heaters be installed so that com­
bustion and ventilation air be taken from outside these

areas.

Refer

to

the

"Facts

to

Consider

About

the

Location” section of this manual and also the latest edi­
tion of the National Fuel Gas Code, ANSI Z223.I, also

referred to as NFPA 54 for specifics prcwided concerning
air required.

AWARNING

A fire can start if combustible materials such as clothing,
cleaning materials, or flammable liquids are placed against
or next to the water heater.

AWARNING

At the time of manufacture this water heater was provid­
ed with a combination temperature-pressures relief valve

certified

by

a

nationally

recognized

testing

laboratory

that maintains periodic inspection of production of listed
equipment

or

materials,

as

meeting

the

requirements

for Relief Valves and Automatic Gas Shutoff Devices for

Hot Water Supply Systems, and the latest edition of

ANSI Z2I.22 and the code requirements of ASME. If

replaced, the valve must meet the requirements of local

codes, but not less than a combination temperature and
pressure relief valve certified as meeting the require­

ments

for

Relief

Valves

and

Automatic

Gas

Shutoff

Devices for Hot Water Supply Systems, ANSI Z2I.22 by

a nationally recognized testing laboratory that maintains

periodic inspection of production of listed equipment or
materials.
The valve must be marked with a maximum set pressure

not to exceed the marked hydrostatic working pressure

of the water heater (ISO Ibs./sq. in.) and a discharge
capacity not less than the water heater input rate as
shown on the model rating plate. (Electric heaters •

watts divided by 1000 x 3415 equal BTU/Hr. rate.)

Your local jurisdictional authority, while mandating the

use

of

a

temperature-pressure

reliqf

vidve

{complying

with ANSI Z2I.22 anc( ASnE,imay requir^ a^ '

'

different from the onelfurnished with фе wat
Compliance with sucH 1оф1 requirements! m

fied by the installer oijend иЦг of thd water

a locally prescribed temberdture-prbssure

: in

Ive model

heater,

be satis-

leater with

jelief valve

the watdr heater in

peatjer,
lesionali

’e ms

lief valve

pening or

installed

installed in the designatecqopmin^

place of the factory futnisfled yalw

For safe operation on the water
must not be removed fr^m ft's
plugged.

I i I

The temperature-pressurt refeef ^

,

directly

into

the

fitting

of

thf

waiter:beAeridesignated

for the relief valve. PopiticAi the valyp d

and pro­

vide tubing so that ally décharge iMlf ex^ oRly within 6

inches above, or at any distance below the structural

floor. Be certain that

tio

contact'is nVSde.;with any live

electrical

part.

The

discharge

opening

must

not

be

blocked or reduced in size under any circumstances.

Excessive length, over 30 feet, or use of more than four

elbows cam cause restriction and reduce the discharge
capacity of the valve.

No valve or other obstruction is to be placed between
the relief valve and the tank. Do not connect tubing

directly to discharge drain unless a 6" air gap is provided.

To prevent bodily injury, hazard to life, or property dam­
age, the relief valve must be allowed to discharge water

in quantities should circumstances demand. If the dis­
charge pipe is not connected to a drain or other suitable

means, die water flow may cause property damage.

The Discharge Pipe:

* Must not be smaller in size than the outlet pipe size of

the valve, or have any reducing couplings or other
restrictions.

* Must not be plugged or blocked.
• Must be of material listed for hot water distribution.

Must be installed so as to allow complete drainage of

both

the

temperature-pressure

relief

valve,

and

the

discharge pipe.

• Must terTnjnate at an adequate drain.
* Must not have any valve between the relief valve and

tank.

Advertising