A caution, Awarning, Facts to consider about the location – Kenmore ECONOMIZER 153.332418 User Manual
Page 9: Installation instructions (cont’d)
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
A CAUTION
WATER HEATERS EVENTUALLY LEAK: Installation of the
water heater must be accomi^ished in such a manner that if
the tank or any connections should teak, the flow of water will
not cause damage to the structure. When such locations cart*
not be avoided, a suitable drain pan should be installed urtder
the water heater. Drain pans are available at your local Sears
store. Such a drain pan must be not greater than
V/,
inches
deep, have a minimum iength and width of at ieast
2
inches
greater than the water heater dimensions and must be piped
to an adequate drain. The pan must not restrict combustion air
flow. Under no circumstances is the manufacturer or Sears to
be held liable for any water damage in connection with this
water heater.
AWARNING
INSTALLATiONS iN AREAS WHERE FLAMMABLE LiQUiDS
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES,
STORAGE,
AND
UTiLITY
AREAS,
ETC):
Flammable liquids (such as gasoline, solvents, propane (LP) or
butane, etc.), all of which emit flammable vapors, may be
improperly stored or used In such areas. The gas water heater
pilot light or main burner can ignite such vapors. The resulting
flashback and fire can cause death or serious bums to anyone in
the area, as weii as property damage.
If installation in such areas is your only option, then the installa
tion must be accomplished in a way that the pilot flame and
main burner flame are elevated from the floor at least 18 inches.
While this rnay reduce the chances of flammable vapors from a
floor spill being ignited, gasoline and other flammable substances
should never be stored or used in the same room or area con
taining a gas water heater or other open flame or spark produc
ing appiiance.
NOTE; Flammable vapors may be drawn by air currents from
other areas of the structure to the appliance.
AWARNING
Propeilants of aerosol sprays and volatile compounds, (clean
ers, chlorine based chemicals, réfrigérants, etc.) in addition to
being highly flammable in many cases, wil) also change to cor
rosive hydrochloric acid when exposed to the combustion
products of the water heater. The results can be hazardous,
and also cause product frulure.
The location selection must provide adequate clearances for ser
vicing and proper operation of the water neater.
Facts to Consider About the
Location
You should carefully choose an indoor location for the new
water heater, because the placement Is a very important consid
eration for the safety of the occupants in the building and for
the most economical use of the appliance.
This water heater is
not for use in mobile homes or outdoor installation.
Whether replacing an old water heater or putting the water
heater in a new location, the following critical points must be
observed.
* The location selected should be indoors as close as practical
to the gas vent or chimney to which the water heater vent is
going to be connected, and as centralized with the water
piping system as possible. The water heater, as all water
heaters,
will
eventually
leak.
Do
not
install
without
adequate drainage provisions where water flow will cause
damage.
Installation Instructions (cont’d)
AWARNING
This water heater must not be installed directly on carpeting.
Carpeting must be protected by a metal or wood panel
beneath the appliance extending beyond the full width and
depth of the appliance by at least 3 inches (76.2mm) in any
direction, or if the appliance is installed in an alcove or closet,
the entire floor must be covered by the panel. Failure to heed
this warning may result in a fire haz^.
AWARNING
Minimum clearances between the water heater and com
bustible or non-combustibte construction are I" at the sides
and rear, 4" at the front, and 6" from the vent pipe. Clearance
from the top of the jacket is 18" on most models. Note that a
lesser dimension may be allowed on some models. Refer to the
label on the water heater adjacent to the gas control valve for
all clearances.
12" MAX.
VENTILATION
AIR -,
OPENINGS'-^
I
i MIN.
I" MIN,
TOP VIEW
OF CLOSET
WITHOUT DOOR
FRONT VIEW
OF DOOR
Figure I
I" MIN.
AWARNING
A.gas water heater cannot operate pn^>eHy without the cor
rect amount of air for combustion. Do not install in a confined
area such a closet, unless you provide air as shown in the “Facts
to Consider About the Location” section. Never obstruct the
flow of ventilation air. If you have any doubts or questions at all,
call your gas company. Failure to provide the proper amount of
combustion air can result in a fire or explosion and can cause
DEATH, SERIOUS BODILY INJUFTf, OR PROPERTY DAMAGE.
AWARNING
If this water heater will be used in beauty shops, barber shops,
cleaning establishments, or self-service laundries with dry
cleaning equipment, it is imperative that the water heater or
water heaters be installed so that combustion and ventilation
air be taken from outside these areas. Refer to the “Facts to
Consider About the Location” section of this manual and also
the latest edition of the National Fuel Gas Code, ANSI Z213.1,
alM referred to as NFPA 54 for specifics provided concerning
air required.