Pdr-04 – Pioneer PDR-04 User Manual

Page 52

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

PDR-04

6.2.3 Coarse Skew Adjustment

Adjustment 1

• Objective

• Symptom when out

of adjustment

To coarse adjust the angle of pickup to the disc for perform the grating and DPP

(tracking offset) adjustments correctly.

Sound broken, some discs can be played but not others.

»Measurement instru­

ment connections

Connect the oscilloscope to
CN204(TP201), Pin 1 (RF)

(SERVO UCOM BOARD assy)

[ Settings ]

20 mV/div.
200 nS/div.

AC mode

• Player state

• Adjustment

location

• Disc

Test mode,focus and spindle servos

closed and tracking servo open.

Radial adjustment screw and

tangential adjustment screw

STD-903

[ Procedure ]

(1) Move the pickup to the position where the radial/tangential adjustment screws will be seen with the MANUAL / TRACK

SEARCH FWD ►► or REV ◄◄ keys so that the radial/tangential adjustment screws can be adjusted.

(2) Press the FINALIZE key, then the PLAY ► key in that order to close the focus servo then the spindle servo.

(3) Adjust the RAD (radial direction) and TAN (tangential direction) adjustment screws alternately with hexagonal screwdriver

(1.27 mm diagonal) to maximize the RF output at CN204 (TP201), Pin 1.

Note : Radial direction and tangential direction mean the direction relative to the disc shown in Fig. 2.

0

Hexagonal

screwdriver

Radial direction

Fig. 2

52

Advertising