10 tracking amp. gain adjustment, Pdr-04 – Pioneer PDR-04 User Manual

Page 61

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

PDR-04

6.3.9 Main and Sub Mix Ratio Adjustment

Adjustment 2

► Objective

• Symptom when out

of adjustment

To mix the gain of the main signal output and sub signal output of the pickup.

Player does not playback.

• Measurement instru­

ment connections

Connect the oscilloscope to
CH1:CN104(TP1), Pint (STE)
CH2: CN104 (TP1), Pin 2 (MSTE)
[These connections must be via

low pass filters. ]

[ Settings ]
cm : 50 mV/div. AC mode

10 mS/div. ADD mode

CH2 : 100 mV/diV. AC mode

> Player state

> Adjustment

location

• Disc

Test mode, focus and spindle servos

closed and tracking servo open

VR110(MS. MIX)

(HEAD BOARD assy)

STD-903

[ Procedure ]

(1 ) Press the FINALIZE key, then the PLAY ► key In that order to close the focus servo then the spindle servo.

(2) Set the oscilloscope to ADD mode (waveform adding mode of CHI and CH2) and observe the adding waveform of CHI

and CH2.

(3) Adjust VR110 (MS. MIX) so that the amplitude of waveform becomes minimum.

6.3.10 Tracking Amp. Gain Adjustment

Adjustment 2

• Objective

• Symptom when out

of adjustment

To correct the discrepancy in the tracking error level with the pickup.

Player does not playback, track search is impossible, tracks are skipped.

» Measurement instru­

ment connections

Connect the oscilloscope to

CN104 (TP1), Pin3(TE)

[These connection must be via a

low pass filter (15kQ + 0.001 pF). ]

[ Settings ]

20 mV/div.

5 mS/dIv.

DC mode

Player state

» Adjustment

location

• Disc

Test mode, focus and spindle servos

closed and tracking servo open

VR111 (TE. GAIN)

(HEAD BOARD assy)

STD-903

[ Procedure ]

(1 ) Move the pickup to midway across the disc (R = 35mm) with the MANUAL / TRACK SEARCH FWD ►► or REV

◄◄ keys.

(2) Press the FINALIZE key, then the PLAY ► key in that order to close the focus servo then the spindle servo.

(3) Line up the bright line (ground) at the center of the oscilloscope screen and put the oscilloscope into DC mode.

(4) Adjust VR111 (TE. GAIN) so that the positive amplitude and negative amplitude of the tracking error signal at CN104

(TP1), Pin 3 (TE) is 1.0V+ 0.05V.

1.0V ± 0.05V

61