2) system serial communication, Pdr-04 – Pioneer PDR-04 User Manual

Page 86

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

PDR-04

(2) System serial communication

The mode controller performed serial communication between
the mechanism controller and LC89585 (digital interface LSI)
and PDC020A (FS converter LSI).
The mechanism controller also performed communication

with LC89585 at the following timings.

© Communication request from mechanism controller.
® Mechanism/mode controller communication

© Communication with mode controUer/LC89585

During this time, XFUSE is set to L and serial communi­

cation of mechanism controll» is disabled.

0 Serial communication with mode controller/LM1972M

© Conununication with mechanism controller/LC89585

BUS

XFUSE

MREQ,
MACK

LREQ

AATLAT

ATIP

Standby

Mechanism
Mode

Mode

LC89585, LM1972M

Mecha.

LC89585

Standby

1® r

uinrinf

"LJ"

®

uir

~IS

■U

Approx. 13.3 mS

(3) Communication with Mechanism Controiier and

Mode Controiier

Communication Format
This CPU and the mechanism control CPU performed serial

conununication with 5 signal lines.

Mechanism

control
CPU

MSCK

FSCK

MSI

-

FSO

MSO

-

FSI

MREQ

-

MREQ

MACK

-

MACK

Mode control
CPU

• FSCK...........................Serial transmission clock (1 MHz)
• FSI/FSO....................... Serial data transmission line
• MREQ/M ACK Handshake line
The communication timing is control by the mechanism

control CPU. 13 byte data is transmitted every 13.33 to 40

ms. (Average:13.33 msec)

Conununication is performed by the following procedure.
© The MREQ signal becomes L as communication request

from the mechanism control microprocessor.

® This microprocessor sets the MACK signal to L as commu­

nication enable signal.

© The mechanism controller sets the MREQ signal to H

after 1 byte serial transmission.

®

This microprocessor sets MACK to H if serial transmis­

sion has ended normally.

© Hereafter © to © are repeated until the 13 byte data

transmission has completed.

^ The mechanism controller and mode controller observes

the state of the other side’s control line, and stops cormnu-

nication processing of transmission if conditions are not

satisfied after a certain time.

86