Cleveland Range Floor Type Gas Convection Steamer 24CGA10.2 User Manual

Page 19

Advertising
background image

Adjust or

replace the

on/off micro

switch

Yes

Connect power

to steamer.

No

Is the red light on?

Is there power to

the steamer?

Is there water in

the sight glass?

Yes

See

Steamer won't

fill.

No

Has the pilot

ignited?

Yes

No

Does the steamer

steam in manual

mode?

Yes

Replace

the timer

Yes

Is there power to

the Timed/Manual

switch?

No

Replace the
wiring to the

switch

Is there power

from the Timed/

Manual switch?

Yes

Replace the

switch

No

Does the steamer

steam with the

door switch

bypassed?

Yes

Replace the

door switch

Yes

Is there 120 VAC

to the R2 relay?

No

PROBLEM:

24CGA6

24CGA10.2

Steamer won't

steam with handle

in on position

Replace

the wiring

to relay

No

Is the fan

turning?

Yes

Is there 120 VAC

to the fan?

Replace

the fan

Check the

R1 relay

Yes

No

Is there 24 VAC to

the main coil of the

gas valve?

Yes

Replace the

gas valve?

Yes

Does the coil to

the main gas valve

get 24 VAC when

the fan prover

switch is

bypassed?

No

Replace the

the fan prover

switch.

Replace the R2

relay.

Yes

No

No

See

Steamer won't

ignite

No

No

Steamer won't

steam