PROBLEM:

24CGA6

24CGA10.2

Steamer won't fill

with the handle in

the on position

Is there power

to the steamer?

Connect

power to the

steamer

No

Is there water to

the steamer?

Yes

Supply

water to the

steamer.

No

Is there 120 VAC

between the

terminals H and N

on the watr level

board?

Yes

Adjust or

replace on/off

micro switch

No

Is there 120 VAC

between terminals

Fill and N on the

water board?

Yes

With the wire

removed from the HI

terminal on the water

level board, is there

120 VAC between

terminals Fill and N?

No

Replace the

water level

board.

No

Is there debris on

the HI probe in the

probe assy?

Yes

Replace the

wire to the HI

probe.

No

Clean or

replace the

probe assy.

Yes

Is there 120 VAC

across the coil of

the fill solenoid?

Yes

Adjust or

replace the on/

off micro switch

No

Is water leaving

the fill solenoid?

Yes

Replace the fill

solenoid.

No

Does the manual

drain valve close

completely?

Yes

Clean or

replace the

drain valve.

No

Yes

Steamer won't

fill