Cleveland Range Floor Type Gas Convection Steamer 24CGA10.2 User Manual

Page 21

Advertising
background image

Is there 120 VAC

between the

terminals Heat and

N on the water

level board with

the the low probe

submerged?

Is there 120 VAC

between Heat and N

terminals on the water

level board with a

jumper between

terminal XL and C?

No

Clean or

replace the

probe assy.

Replace water

level board.

No

Yes

Is there 120 VAC

across the primary

of the 24 VAC

ignition

transformer?

yes

Is there 24 VAC to

the secondary of

the ignition

transformer?

Yes

Is there 24 VAC to

the ignition

module?

Yes

Replace the

transformer

No

Replace the wires

to the ignition

module.

No

Is there spark from

the module until

the 90-second lock

out?

Yes

Replace the

ignition module

No

Is there 24 VAC to

the pilot coil on the

gas valve until the

90-second lock

out?

Yes

No

Does the steamer

have gas supplied?

Yes

Supply gas to

the steamer

No

Does the pilot gas

valve open when

the 24 VAC is

applied?

Replace the

gas valve.

No

Is spark generated

at the igniter?

Yes

Replace the

igniter and

wire

No

Is there at least
1.0 micro amps

DC at the burner

ground terminal on

the ignition

module?

Yes

Replace the

ignition module

Yes

Is the pilot flame

blue and

enveloping the

igniter?

Replace the

ground wire

Yes

Replace the

pilot assy

No

Replace

the high

limit

No

Yes

Is the red light on?

Is there power to

the steamer?

Connect power

to the steamer

No

No

Adjust or

replace the

on/off micro

switch

Is there water in

the sight glass?

Yes

Yes

Yes

See

Steamer won't

fill

No

PROBLEM:

24CGA6

24CGA10.2

Steamer won't

ignite

No

Steam generator

won't ignite